“…Interpretation for these differences is that intermolecular deactivations of the excited states (mainly by collisional quenching) are temperature-dependent processes that are by nature function of the quencher type and hence the liquid solvent containing the dye molecules. Based on previous works (Lavieille et al 2004), an appropriate fitting of the calibration curves is provided by:…”
Section: Droplet Temperature Measurementsmentioning
“…Interpretation for these differences is that intermolecular deactivations of the excited states (mainly by collisional quenching) are temperature-dependent processes that are by nature function of the quencher type and hence the liquid solvent containing the dye molecules. Based on previous works (Lavieille et al 2004), an appropriate fitting of the calibration curves is provided by:…”
Section: Droplet Temperature Measurementsmentioning
“…Emission of OBN becomes visible in addition to PM597's fluorescence. Lasing that occurs for OBN now, is not visible in the given diagram, but definitively takes place for wavelengths higher than 660 nm 8 . Validity of 2cLIF theory for the chosen dye concentrations and subsequent energy transfer has been proven in our previous investigations [2]: although EET causes saturation of spontaneous fluorescence emission in the 2cLIF wavelength bands, self-similarity of the normalized emission spectrum remains and thus 2cLIF theory yields.…”
Section: Development Steps Of Pulsed 2d-2clif With Mdr-enhanced Energmentioning
confidence: 99%
“…different types of fluorophores for various liquids [6,7] or a third PMT for an additional wavelength band that accounts for self-absorption effects of a single dye [8]. More interestingly, latest 2cLIF publications consider a pulsed laser for fluorescence excitation [2,9,10].…”
A new method for instantaneous measurement of temperature, size and velocity of micro-droplets has been developed. The method is based on the well-known 2-color laser-induced fluorescence (2cLIF) technique, but uses a pulsed laser for 2-dimensional imaging without motion blur and an adjusted dye mixture for suppression of LIFMDRs by utilizing the MDR-enhanced energy transfer effect. This work presents the development steps that are necessary to verify feasibility of pulsed 2D-2cLIF-EET for micro droplet and hollow-cone spray applications.
“…In this figure, values of b are significantly lower in the yellow-green region of the fluorescence spectrum than in the red edge spectral region. Based on experimental measurements, Lavieille et al (2004) suggested the following expression for the fluorescence intensity I f,i detected over a specific spectral band noted i: …”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.