2014
DOI: 10.1016/j.mri.2014.01.015
|View full text |Cite
|
Sign up to set email alerts
|

Non-Gaussian water diffusion kurtosis imaging of prostate cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

7
53
0
1

Year Published

2015
2015
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 78 publications
(61 citation statements)
references
References 38 publications
7
53
0
1
Order By: Relevance
“…A very important part of these differences is the choice of optimal number, range, and position of b values. For previous studies of DK imaging in the prostate, the b value spectrum was mostly 0-2,000 s/mm 2 , except in the study by Tamura et al (0-1,500 s/mm 2 ) [22][23][24]34]. It is suggested from the study about the optimization of b value distribution for different mathematical models of prostate that, the parameters of the DK model were best estimated using 5 to 7 b values in the ranges of 300 to 2,000 s/mm 2 , in addition to low b value [35].…”
Section: Median Kapp (Au)mentioning
confidence: 97%
See 2 more Smart Citations
“…A very important part of these differences is the choice of optimal number, range, and position of b values. For previous studies of DK imaging in the prostate, the b value spectrum was mostly 0-2,000 s/mm 2 , except in the study by Tamura et al (0-1,500 s/mm 2 ) [22][23][24]34]. It is suggested from the study about the optimization of b value distribution for different mathematical models of prostate that, the parameters of the DK model were best estimated using 5 to 7 b values in the ranges of 300 to 2,000 s/mm 2 , in addition to low b value [35].…”
Section: Median Kapp (Au)mentioning
confidence: 97%
“…Thus, we concluded that the DK model with entire-tumor histogram analysis is a more promising way for determining pathologic Gleason grade of PCa preoperatively. Application of the DK model for quantitation of DW imaging in the prostate has been gaining increasing interest in recent years [20,21,23,24]. Although still with many dissents, the DK model seemed to be the preferred model considering the model fit and repeatability with b values up to 2,000 s/mm 2 [32,33].…”
Section: Median Kapp (Au)mentioning
confidence: 99%
See 1 more Smart Citation
“…In order to achieve the best correlation of morphologic changes between CT and MRI modalities, b value of 0 s/mm 2 was used. Likewise, to ensure a large enough effect on the DWI signal, b value of 2000 s/mm 2 was used (23,25).…”
Section: Mri Protocolmentioning
confidence: 99%
“…Consequently, interest in DKI for body imaging is growing [29] with demonstrated applications in imaging of liver [30,31], kidney [32,33], and prostate [34][35][36].…”
Section: Introductionmentioning
confidence: 99%