Noise power spectral characteristics of an inductively coupled plasma-mass spectrometer

Abstract: The noise power spectra of 85Rb+ signal and MNb+ signal from an Inductively coupled plasma mass spectrometer were measured at the same plasma conditions as were those of Sr II emission from the plasma Itself. Comparison of these spectra showed that discrete frequency noise In the emission at the mass spectrometer sampling orifice Is nearly Identical with that In the mass spectrometrlc signal and that white noise In the mass spectrometer signal was higher than that found In the emission signal. The dependence o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
24
0
1

Year Published

1989
1989
2015
2015

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 47 publications
(28 citation statements)
references
References 32 publications
3
24
0
1
Order By: Relevance
“…Полученный ги-бридный двухцелевой инструмент получил назва-ние POEMS (Plasma Optical Emission and Mass Spectrometer) [20][21][22]. Идея его создания опиралась, в частности, на выполненные ранее соответствую-щие эксперименты [23,24]. При создании этого ги-брида исходили, по-видимому, из того, что POEMS, предоставляющий возможности двух методов в од-ном приборе, стоил дешевле, чем комплект из двух отдельных ИСП-МС и ИСП-АЭС спектрометров.…”
Section: таблицаunclassified
“…Полученный ги-бридный двухцелевой инструмент получил назва-ние POEMS (Plasma Optical Emission and Mass Spectrometer) [20][21][22]. Идея его создания опиралась, в частности, на выполненные ранее соответствую-щие эксперименты [23,24]. При создании этого ги-брида исходили, по-видимому, из того, что POEMS, предоставляющий возможности двух методов в од-ном приборе, стоил дешевле, чем комплект из двух отдельных ИСП-МС и ИСП-АЭС спектрометров.…”
Section: таблицаunclassified
“…The source of much of this variance comes from multiplicative phenomena; it affects all signals in the same manner, and by an amount proportional to the signal amplitude. In particular, the ICP is known to suffer from a source of correlated noise known as whistle noise, which typically occurs in the audible range, as well as flicker (1/f) and white noise [24][25][26][27].…”
Section: Inductively-coupled Plasma Mass Spectrometrymentioning
confidence: 99%
“…A schematic of the ICP /MS instrument used in this work is shown in Figure 1. This instrument and some components have been described in detail elsewhere [19][20][21]. Operating conditions are identified in Table 1.…”
Section: Rep / Ms Apparatusmentioning
confidence: 99%