2021
DOI: 10.1016/j.snb.2020.128825
|View full text |Cite
|
Sign up to set email alerts
|

NFC-enabling smartphone-based portable amperometric immunosensor for hepatitis B virus detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
61
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 93 publications
(68 citation statements)
references
References 55 publications
0
61
0
Order By: Relevance
“…Anti-HBsAg was capped in the β -cyclodextrin, and HBsAg was directly measured without tagging. The amperometric signal was recorded in the absence and the presence of HBsAg [ 28 ]. The proposed device has shown a promising portable device for rapid and reliable detection of HBsAg with satisfying performance.…”
Section: Common Methods For Detection Of Hepatitis B Virusmentioning
confidence: 99%
See 1 more Smart Citation
“…Anti-HBsAg was capped in the β -cyclodextrin, and HBsAg was directly measured without tagging. The amperometric signal was recorded in the absence and the presence of HBsAg [ 28 ]. The proposed device has shown a promising portable device for rapid and reliable detection of HBsAg with satisfying performance.…”
Section: Common Methods For Detection Of Hepatitis B Virusmentioning
confidence: 99%
“…Anti-HBsAg was capped in the β-cyclodextrin, and HBsAg was directly measured without tagging. e amperometric signal was recorded in the absence and the presence of HBsAg [28].…”
Section: 52mentioning
confidence: 99%
“…A completely disposable NFC-based electrochemical point-of-care immunosensor has also been developed for detecting viruses such as the hepatitis B virus, providing a viable alternative to current disposable electrochemical point-of-care diagnostics, which require a dedicated reader (for example, glucose test strips) 4 .…”
Section: Current Nfc-based Sensing Technologiesmentioning
confidence: 99%
“…Most NFC-based sensors depend on microcontroller-based multicomponent designs; the versatility (and underused capabilities) of these designs, however, comes at a premium. First examples of application-specific integrated circuits (ASICs) have already been developed for low-cost NFC-based sensors (for example, potentiostat), but a large gap remains between available and required technologies, owing to high initial investments needed for the development of ASICs 4 .…”
Section: Future Requirements For Materialsmentioning
confidence: 99%
“…This paper-based electrochemical sensor achieved a LOD of 85 pM. A simple and user-friendly biosensor was developed exploiting the use of a smartphone to establish a near field communication (NFC) enabled platform [ 91 ]. The entire setup was consisting of an NFC antenna, potentiostat circuit, and connections to an electrode.…”
Section: Spes For Detection Of Virusesmentioning
confidence: 99%