Next‐generation polymerized human hemoglobins in hepatic bioreactor simulations

Abstract: Hepatic hollow fiber (HF) bioreactors can be used to provide temporary support to patients experiencing liver failure. Before being connected to the patient's circulation, cells in the bioreactor must be exposed to a range of physiological O 2 concentrations as observed in the liver sinusoid to ensure proper performance. This zonation in cellular oxygenation promotes differences in hepatocyte phenotype and may better approximate the performance of a real liver within the bioreactor. Polymerized human hemoglobi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
15
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 13 publications
(16 citation statements)
references
References 45 publications
1
15
0
Order By: Relevance
“…The final product was stored at 10 g dl À1 and À80 C until use. 6 Storage in this manner has been shown to maintain T-state PolyhHb as a stable colloidal suspension for at least 2 years with proper thawing before in vivo use. 38…”
Section: Polyhhb Synthesismentioning
confidence: 99%
“…The final product was stored at 10 g dl À1 and À80 C until use. 6 Storage in this manner has been shown to maintain T-state PolyhHb as a stable colloidal suspension for at least 2 years with proper thawing before in vivo use. 38…”
Section: Polyhhb Synthesismentioning
confidence: 99%
“…The hHb/ PolyhHb kinetics of O 2 offloading ( k off ,O 2 ) were measured with an Applied Photophysics SF-17 microvolume stopped-flow spectrophotometer (Applied Photophysics Ltd., Surrey, United Kingdom) using protocols previously described by Rameez and Palmer [51][52][53] . The MW distribution was estimated using an Acclaim SEC-1000 column (Thermo Scientific, Waltham, MA) on a Thermo Scientific Dionex Ultimate UHPLC system using previously described methods 17,54 . Dorsal chamber window model.…”
Section: Methodsmentioning
confidence: 99%
“…[27][28][29] The MW distribution was estimated by using an Acclaim SEC-1000 column (Thermo Scientific, Waltham, MA) connected to a Thermo Scientific Dionex Ultimate UHPLC system using previously described methods. 14,30 All measurements were taken from the same sample used in the animal study.…”
Section: Polyhb Synthesis and Biophysical Propertiesmentioning
confidence: 99%
“…The resulting changes in size distribution after Hp binding was estimated with SEC-HPLC by using previously described methods. 14,30 All measurements were taken from the same sample used in the animal study.…”
Section: Hp Purification and Biophysical Propertiesmentioning
confidence: 99%