1977
DOI: 10.1161/01.cir.56.4.506
|View full text |Cite
|
Sign up to set email alerts
|

New vistas for the study of structural and functional dynamics of the heart, lungs, and circulation by noninvasive numerical tomographic vivisection.

Abstract: Major segments of the biologic sciences and the practice of medicine are based on study and knowledge of the relationships of anatomic structure to biologic function. Traditionally, this knowledge has been gained by indirect means, inference, or by direct surgical vivisection or postmortem examination. The revolutionary capability of nondestructive, operator interactive, mathematical vivisection provided by synchronous cylindrical scanning tomography to obtain similar information non-invasively and painlessly … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

1979
1979
1987
1987

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 34 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…the Dynamic Spatial Reconstructor (DSR). The DSR is designed to scan up to 240 l-mm thick cross sections within a duration of 11 msec, and to repeat this complete scan procedure at &-set intervals, allowing the entire three-dimensional anatomic extent, as well as the dynamic changes in shape and dimensions, of moving structures such as the intact beating heart, lungs, and vascular system to be reconstructed (4)(5)(6)(7)(8). Figure 1 depicts in schematic form the multiple X-ray source and detector assemblies of a proposed Dynamic Spatial Reconstructor system, consisting of a set of 28 independently controlled rotating-anode X-ray sources arranged around a semi-circle with a radius of 143 cm, and a 30-cm wide fluorescent screen bent around an opposing semicircle with a radius of 58 cm.…”
Section: The Dynamic Spatial Reconstructormentioning
confidence: 99%
See 2 more Smart Citations
“…the Dynamic Spatial Reconstructor (DSR). The DSR is designed to scan up to 240 l-mm thick cross sections within a duration of 11 msec, and to repeat this complete scan procedure at &-set intervals, allowing the entire three-dimensional anatomic extent, as well as the dynamic changes in shape and dimensions, of moving structures such as the intact beating heart, lungs, and vascular system to be reconstructed (4)(5)(6)(7)(8). Figure 1 depicts in schematic form the multiple X-ray source and detector assemblies of a proposed Dynamic Spatial Reconstructor system, consisting of a set of 28 independently controlled rotating-anode X-ray sources arranged around a semi-circle with a radius of 143 cm, and a 30-cm wide fluorescent screen bent around an opposing semicircle with a radius of 58 cm.…”
Section: The Dynamic Spatial Reconstructormentioning
confidence: 99%
“…In addition to the resulting unsatisfactory delay between scan and diagnosis for any one patient, scanning of more than six patients per day would effectively be prevented, even though each scan procedure would involve approximately 1 hr. Consequently, use of the DSR as a routine cost-effective clinical diagnostic technique for early detection and study of cardiovascular abnormalities and early lung cancer would be impossible (4,7,8). It is anticipated that reconstruction times for each 127.…”
Section: Applications Of the Dsrmentioning
confidence: 99%
See 1 more Smart Citation
“…Nevertheless on the basis of technological advances now in the wings, Dr. Wood remains convinced that the dream of noninvasive vivisection of structural-functional dynamics of the heart, lungs, and circulation in health and disease will before 2000 AD become a reality in major biomedical centers around this globe (Wood, 1977(Wood, , 1978(Wood, , 1985a.…”
mentioning
confidence: 99%