“…To our knowledge, this clinical study is today the only one that documents a large number of cases treated with the present new method of guided surgery, in which the handpiece is guided rather than the drills. In fact, in the literature, there are only two studies of this system for guided surgery [34, 35].…”
Section: Discussionmentioning
confidence: 99%
“…To our knowledge, this clinical study is today the only one that documents a large number of cases treated with the present new method of guided surgery, in which the handpiece is guided rather than the drills. In fact, in the literature, there are only two studies of this system for guided surgery [34, 35].…”
Section: Discussionmentioning
confidence: 99%
“…This deviation can be a result of multiple sources: from the imaging process, data transfer, template manufacture, inaccurate positioning of the guide in the mouth, and drill errors . These variables may influence the angulation, length, and diameter of the osteotomy as well as implant insertion that translates to deviations in implant position …”
Section: Introductionmentioning
confidence: 99%
“…These variables may influence the angulation, length, and diameter of the osteotomy as well as implant insertion that translates to deviations in implant position. [12][13][14][15][16][17] A meta-analysis focusing on trials with patients, by Tahmaseb et al, 18 concluded that the accuracy of sCAIS is within the clinically acceptable range in the majority of the cases, however, a safety margin of at least 2 mm should be respected. Inaccurate implant positioning can directly compromise the final prosthetic outcome and safety of the surgical procedure.…”
mentioning
confidence: 99%
“…We hypothesize that the control of these variables would improve the predictability and accuracy of treatment outcomes. Notably, drill guidance and drill related deviations have been shown to have a significant impact on the accuracy of implant placement . Nevertheless, the effect of the different components involved in the drill guidance process is still poorly understood.…”
Section: Introductionmentioning
confidence: 99%
“…Notably, drill guidance and drill related deviations have been shown to have a significant impact on the accuracy of implant placement. 19 Nevertheless, the effect of the different components involved in the drill guidance process is still poorly understood. Consequently, this study specifically aims to investigate the effect of sleeve height, drilling distance and drilling key height on the accuracy of dental implants placed with a sCAIS approach.…”
Section: Introductionmentioning
confidence: 99%