2019
DOI: 10.1186/s12903-019-0940-0
|View full text |Cite
|
Sign up to set email alerts
|

A novel guided surgery system with a sleeveless open frame structure: a retrospective clinical study on 38 partially edentulous patients with 1 year of follow-up

Abstract: BackgroundThis retrospective clinical study aims to present results of experience with a novel guided surgery system with a sleeveless, open-frame structure, in which the surgical handpiece (not the drills used for preparation) is guided.MethodsThis study was based on an evaluation of the records of partially edentulous patients who had been treated with a sleeveless open-frame guided surgery system (TWIN-Guide®, 2Ingis, Brussels, Belgium), between January 2015 and December 2017. Inclusion criteria were patien… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
47
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 33 publications
(49 citation statements)
references
References 39 publications
1
47
0
1
Order By: Relevance
“…Most implant manufacturers require a drill guide and/or a specialized guided surgical osteotomy kit. There are only a few implant manufacturers who promote surgical guides without the need to use a drill guide and the metal sleeve (R2 Navi Guide™, Megagen, Daegu, South Korea), which empirically is proven to be clinically reliable [ 46 , 47 ].…”
Section: Additive Manufacturingmentioning
confidence: 99%
“…Most implant manufacturers require a drill guide and/or a specialized guided surgical osteotomy kit. There are only a few implant manufacturers who promote surgical guides without the need to use a drill guide and the metal sleeve (R2 Navi Guide™, Megagen, Daegu, South Korea), which empirically is proven to be clinically reliable [ 46 , 47 ].…”
Section: Additive Manufacturingmentioning
confidence: 99%
“…(A) Endoral periapical radiograph taken at the beginning of the restorative process, before the first intraoral scan, with the healing abutment in position. (B) Three years later, the crown is in function and seated with high precision over the abutment, with little or no gap (surgical [8,33], prosthetic [2-5, 10, 30] and orthodontic [34]) that will then be produced physically for clinical use but also to instruct the same software so that it 'learns' certain mechanisms, and can therefore respond or act automatically, with an overall benefit for the workflow in terms of reducing processing times and costs [9]. In the field of implant prosthodontics, for example, the new digital workflows involve the use of intraoral scanners to capture the position of the implants through the scanbody, the digital version of the old implant transfer [6][7][8][9].…”
Section: Discussionmentioning
confidence: 99%
“…Besides, surgical procedure is performed with continuous irrigation of the osteotomy site. The guide uses the pattern of the open frame, giving the clinician the guidelines for the implantation in the form of two reference cylindrical bushings places on the vestibular and oral sides of the surgical guide [23,25].…”
Section: Dynamic and Static Navigationmentioning
confidence: 99%
“…Kao glavni, navode se nedovoljna preglednost operativnog polja, nemogućnost primene hirurškog vodiča u slučaju malog interokluzalnog prostora, opasnost od oštećenja ili kontaminacije svrdla prilikom prolaska kroz cilindar vođice [23]. Da bi se nadomestili pomenuti nedostaci, danas se uveliko razvija metoda ugradnje implantata primenom otvorenog vodiča (TWIN-Guide®, 2Ingis, Brussels, Belgium) [23,25]. Otvoren dizajn kompenzuje navedene nedostatke zatvorenog sistema vodiča i kompatibilan je sa svim implantološkim sistemima.…”
Section: Dinamička I Statička Navigacijaunclassified