2002
DOI: 10.1111/j.1365-2621.2002.tb08693.x
|View full text |Cite
|
Sign up to set email alerts
|

New HPLC Method to Determine Ethyl Carbamate in Alcoholic Beverages Using Fluorescence Detection

Abstract: A new methodology to the quantification of ethyl carbamate (EC) has been developed. This method allows the analysis by HPLC of ethyl carbamate in samples of wine, fortified wine, and wine brandy, by a precolumn derivatization with 9-xanthydrol, and fluorescence detection. This does not require previous sample extraction or concentration. The method presents an average recovery of 96% among samples studied, a detection limit of 4.2 µg/L, and an average intermediate precision of 6.3%. The comparison of the resul… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
47
3
3

Year Published

2008
2008
2015
2015

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 64 publications
(54 citation statements)
references
References 9 publications
1
47
3
3
Order By: Relevance
“…The values were 3.81 and 11.53 μg L À1 , respectively. Values shown are in the range of other studies that have applied the same technique, with detection limits ranging from 0.02 to 4.20 μg L À1 and quantification limits varying from 0.05 to 4.00 mg L À1 (16,17,25,26). The concentrations of EC encountered in samples of cachaça stored in the presence and absence of light and analysed every 2 months for 6 months are described in Table 1.…”
Section: Resultsmentioning
confidence: 95%
“…The values were 3.81 and 11.53 μg L À1 , respectively. Values shown are in the range of other studies that have applied the same technique, with detection limits ranging from 0.02 to 4.20 μg L À1 and quantification limits varying from 0.05 to 4.00 mg L À1 (16,17,25,26). The concentrations of EC encountered in samples of cachaça stored in the presence and absence of light and analysed every 2 months for 6 months are described in Table 1.…”
Section: Resultsmentioning
confidence: 95%
“…Alguns trabalhos realizados com diferentes bebidas alcoólicas têm apresentado valores que variam de 1,64 a 4,2 μg L -1 , para o limite de detecção, e de 3,56 μg L -1 a 4 mg L -1 , para o limite de quantificação. 6,12,13 A Tabela 1 mostra os resultados obtidos para a quantificação do CE nas frações "cabeça", "coração" (cachaça nova) e "calda".…”
Section: Resultsunclassified
“…[12][13][14] Os reagentes empregados para análise foram padrão de carbamato de etila (Acros Organics), etanol, propanol, hexano, ácido clorídrico (HCl), acetato de etila, acetato de sódio, acetonitrila grau HPLC (Merck), água ultrapura e 9-xantidrol (Acros Organics). Para as análises, foi realizada a purificação do 9-xantidrol por meio de sucessivas recristalizações em hexano.…”
Section: Reagentes E Padrõesunclassified
“…Under these conditions, many reactions can occur leading to significant changes in wine, some are crucial to the final remarkable characteristics of Madeira wine, however it may also cause production of ethyl carbamate (EC). According to Stevens and Ough [2], under fairly normal storage temperatures (13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24) • C), and not uncommon concentrations of urea (1-10 mg/L), a significant amount of EC will accumulate in wine.…”
Section: Introductionmentioning
confidence: 99%
“…Several extraction methodologies have been used, such as continuous liquid-liquid extraction [13], and solid phase extraction [7,14,15], combined with one-dimensional gas chromatography coupled with mass spectrometry detection (GC-MS). EC has been determined in fortified Madeira wines by SPE followed by GC-MS [15,16], and by derivatization with 9-xanthydrol, followed by high performance liquid chromatography (HPLC) [17]. More recently, a solvent-free methodology was used: solid phase microextraction (SPME) [9,18,19].…”
Section: Introductionmentioning
confidence: 99%