New double-stapling technique for esophagojejunostomy and esophagogastrostomy in gastric cancer surgery, using a peroral intraluminal approach with a digital stapling system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 15 publications
(24 reference statements)
0
8
0
Order By: Relevance
“…This double stapling technique was first introduced in colorectal surgery (particularly rectal cancer) for use in a narrow operative field, and its safety in colorectal surgery has already been reported and demonstrated in many studies [26][27][28][29] . Thus, the double stapling technique can be useful and time-saving for esophagojejunostomy after LTG, and recent studies have reported on its safety [23,30,31] . There was only one anastomotic stricture after discharge (a late complication), and there were no major complications, such as anastomotic leak, in the present study.…”
Section: Discussionmentioning
confidence: 99%
“…This double stapling technique was first introduced in colorectal surgery (particularly rectal cancer) for use in a narrow operative field, and its safety in colorectal surgery has already been reported and demonstrated in many studies [26][27][28][29] . Thus, the double stapling technique can be useful and time-saving for esophagojejunostomy after LTG, and recent studies have reported on its safety [23,30,31] . There was only one anastomotic stricture after discharge (a late complication), and there were no major complications, such as anastomotic leak, in the present study.…”
Section: Discussionmentioning
confidence: 99%
“…The iDrive is a type of Intelligent Surgical Instrument (Power Medical Interventions) that is designed to transect, resect, and anastomose tissue. [14][15][16][17] It has a control unit, called the digital loading unit (DLU), to control the accurate placement of the cartridge. Each DLU contains a programmed electronic device that triggers activation of the appropriate program in the main microprocessor.…”
Section: Materials and Methods Anastomotic Device (Idrive)mentioning
confidence: 99%
“…If there is any problem, such as excessive tissue thickness, the surgeon is alerted that the system is out of stapling range, which ensures safety. [14][15][16][17] We used a disposable circular stapler 25 (CS 25) as the DLU installed in the iDrive for this study. Clinically, the CS 25 is used for intestinal anastomosis.…”
Section: The Controlled Tissue Compression Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Some surgeons have reported the use of extracorporeal approaches through mini-laparotomy [7,8], which may spoil the cosmetic benefits of laparoscopic surgery. Another approach involves side-to-side anastomosis using a linear stapler [9,10].…”
Section: Introductionmentioning
confidence: 99%