2003
DOI: 10.1097/01.rli.0000077124.24140.bd
|View full text |Cite
|
Sign up to set email alerts
|

New Contrast Media Designed for X-Ray Energy Subtraction Imaging in Digital Mammography

Abstract: The instrumental and physical data outlined predestine Zr as contrasting element with a high potential for energy subtraction imaging in digital mammography in the energy range conventionally applied.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
3

Year Published

2004
2004
2011
2011

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 29 publications
(13 citation statements)
references
References 23 publications
0
10
0
3
Order By: Relevance
“…It is likely that a contrast agent with a K-edge close to the center of the mammography energy region ͑i.e., atomic numbers ϳ39-53͒ would improve the results due to a more optimal bin count fraction. Zirconium has been suggested, 29 but the K-edge at 18.0 keV might instead be too low for optimal performance in our case. Iodine concentrations of 3-4 mg/ml have been found reasonable for tumor uptake.…”
Section: Iiib the Experimental Setupmentioning
confidence: 99%
“…It is likely that a contrast agent with a K-edge close to the center of the mammography energy region ͑i.e., atomic numbers ϳ39-53͒ would improve the results due to a more optimal bin count fraction. Zirconium has been suggested, 29 but the K-edge at 18.0 keV might instead be too low for optimal performance in our case. Iodine concentrations of 3-4 mg/ml have been found reasonable for tumor uptake.…”
Section: Iiib the Experimental Setupmentioning
confidence: 99%
“…No uptake of iodine contrast material was observed in 7 of 12 cases with suspicious lesions in standard mammography which were proven to be benign [36]. Moreover, newly designed contrast media could optimize contrast-enhanced techniques in digital mammography [37].…”
Section: Perspectives and Future Aspectsmentioning
confidence: 97%
“…As with breast MRI and breast CT (see text that follows), the contrast agent preferentially collects in the interstitium of cancers rather than normal tissue. An iodine-based contrast agent, such as that used for routine clinical applications in body and brain CT scanning, is used for CEDM, although gadolinium 29 and even zirconium-based 30 agents have also been proposed.…”
Section: Contrast-enhanced Digital Mammographymentioning
confidence: 99%