2012
DOI: 10.1063/1.4750195
|View full text |Cite
|
Sign up to set email alerts
|

New beam line for time-of-flight medium energy ion scattering with large area position sensitive detector

Abstract: A new beam line for medium energy ion mass scattering (MEIS) has been designed and set up at the Ångström laboratory, Uppsala University, Sweden. This MEIS system is based on a time-of-flight (ToF) concept and the electronics for beam chopping relies on a 4 MHz function generator. Repetition rates can be varied between 1 MHz and 63 kHz and pulse widths below 1 ns are typically obtained by including beam bunching. A 6-axis goniometer is used at the target station. Scattering angle and energy of backscattered io… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
43
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
10

Relationship

4
6

Authors

Journals

citations
Cited by 61 publications
(45 citation statements)
references
References 19 publications
0
43
0
Order By: Relevance
“…37 Atomic and molecular ions with primary energies E 0 in the range of 25-170 keV were employed: Molecular ions (H 2 + and D 2 + ) extend the range of accessible energies to E 0 /2, where vicinage effects 38 are negligible. 39 Sets of thin films of amorphous Au and Pt were evaporated in different thicknesses on top of cleaned Si wafers using a high-fluence evaporation system.…”
Section: Methodsmentioning
confidence: 99%
“…37 Atomic and molecular ions with primary energies E 0 in the range of 25-170 keV were employed: Molecular ions (H 2 + and D 2 + ) extend the range of accessible energies to E 0 /2, where vicinage effects 38 are negligible. 39 Sets of thin films of amorphous Au and Pt were evaporated in different thicknesses on top of cleaned Si wafers using a high-fluence evaporation system.…”
Section: Methodsmentioning
confidence: 99%
“…The energy-loss experiments were performed with the time-of-flight MEIS (TOF-MEIS) setup at Uppsala University [45]. A large solidangle microchannel-plate (MCP) detector (the diameter of the active area was 120 mm at a distance of 300 mm, which results in a ß0.12 sr solid angle) which can be rotated around the sample permits one to record position-sensitive time spectra for different scattering angles in backscattering geometry.…”
Section: Experiments and Evaluationmentioning
confidence: 99%
“…Time-of-flight elastic recoil detection (TOF-ERD) measurements at Uppsala University yielded the expected stoichiometry and impurity concentrations below ~ 2 %. Time-of-flight medium energy ion scattering (TOF-MEIS) [33] was employed to check the homogeneity of thin film samples. TOF-LEIS spectra were recorded using hydrogen and deuterium beams (monomers and dimers) in the range of 0.5 keV/u -10 keV/u.…”
Section: (1 Kev Protons)mentioning
confidence: 99%