2016
DOI: 10.1159/000452124
|View full text |Cite
|
Sign up to set email alerts
|

New Approach to the Analysis of Raw Data from the Ocular Response Analyzer

Abstract: Purpose: The aim of this research was to present a new approach for the potential characteristics of the anterior eye, based on numerical analysis of the raw data from multiple measurements on 1 eye captured with use of the Ocular Response Analyzer (ORA). Methods: The measurements were carried out 6 times on every eye, one by one, on 29 patients using the ORA. Dependencies between values of 6 applanation pressures P1 and P2 from 1 eye and the new proposed time-dependent parameters sm and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 16 publications
(18 reference statements)
0
7
0
Order By: Relevance
“…Corneal hysteresis (CH) represents the difference between the two pressure determinations, P1 and P2, reflecting the capacity for absorption of kinetic energy in the tissue, an indicator of corneal viscosity. The mean of the two pressure measurements (P1 and P2) determines the Goldmann correlated intraocular pressure (IOPg) [ 11 - 13 ].…”
Section: Introductionmentioning
confidence: 99%
“…Corneal hysteresis (CH) represents the difference between the two pressure determinations, P1 and P2, reflecting the capacity for absorption of kinetic energy in the tissue, an indicator of corneal viscosity. The mean of the two pressure measurements (P1 and P2) determines the Goldmann correlated intraocular pressure (IOPg) [ 11 - 13 ].…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, the measurements performed on a rigid glass lenses [12] presented the lack of applanation associated with almost identical air pressure curves for every single measurement, due to complete pressure ejection from the pump. Access to raw data offered by ORA device, gives possibility to define own, new parameters of the anterior eye, which can be useful in new approach to ophthalmic diagnosis [13].…”
Section: Introductionmentioning
confidence: 99%
“…The averaged values obtained from these few measurements can be used as characteristic value of obtained parameters. However, as it was shown in the paper [22] there exists some individual dependency between P 1 , P 2 pressures and some other raw parameters from different measurements, characteristic for the patient. So, such approach needs a few measurements on a single patient eye to define new characteristic parameters.…”
Section: Introductionmentioning
confidence: 85%
“…First, the Gaussian filter (size of window 17 data points) was applied for smoothing both curves. As in our previous work, measurements below 2 in the waveform score quality parameter were rejected from further processing due to their noise [22]. Four consecutive measurements with the waveform score greater than 2 were analyzed.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation