2022
DOI: 10.1016/j.physo.2022.100114
|View full text |Cite
|
Sign up to set email alerts
|

Neutron personal dosimetry using polyallyl diglycol carbonate (PADC): Current status, best practices and proposed research

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 58 publications
0
3
0
Order By: Relevance
“…Those geometries are depicted in the upper part of Fig 1 . Within the voxels are MgB 4 O 7 doped with 0.5% Dy 3+ (2.56 g/cm 3 ) phosphor powders dispersed by PTFE (C 2 F 4 , 2.2 g/cm 3 ) [21]. The film is attached to human phantom, which is block in shape and consists of two layers: the outer one signifies clothing made from polyethyl terephthalate (PET, C 10 H 8 O 4 , 1.37 g/cm 3 ) and the inner one represents human body in its elemental composition (ICRP Publication 123, 2013) [22]. All elements are assumed to be in their natural abundances.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Those geometries are depicted in the upper part of Fig 1 . Within the voxels are MgB 4 O 7 doped with 0.5% Dy 3+ (2.56 g/cm 3 ) phosphor powders dispersed by PTFE (C 2 F 4 , 2.2 g/cm 3 ) [21]. The film is attached to human phantom, which is block in shape and consists of two layers: the outer one signifies clothing made from polyethyl terephthalate (PET, C 10 H 8 O 4 , 1.37 g/cm 3 ) and the inner one represents human body in its elemental composition (ICRP Publication 123, 2013) [22]. All elements are assumed to be in their natural abundances.…”
Section: Methodsmentioning
confidence: 99%
“…This dosimeter could detect the minimum neutron energy of 100 keV without a neutron converter. Some factors can affect the neutron sensitivity such as the material quality, chemical etching, and the features of the reading system adopted for track analysis [3]. Meanwhile, luminescence dosimeters make use of lithium-6 or boron-10 isotopes which undergo fission from neutron capture.…”
Section: Introductionmentioning
confidence: 99%
“…In this study, we employ PADC detectors for slow neutrons through an n-alpha process. PADC is widely used for personal neutron dosimetry [3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…The ever-challenging issue of neutron dosimetry is discussed in two papers, by Bolzonella et al (2022) and by Gómez-Ros et al (2023). The former discuss the fundamentals and current best practices while the latter illustrate new directions using a wide variety of dosimetry techniques.…”
mentioning
confidence: 99%