2016
DOI: 10.1016/j.radphyschem.2016.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Neutron dose estimation in a zero power nuclear reactor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 30 publications
0
5
0
Order By: Relevance
“…The RA-0 Nuclear Reactor, a zero power reactor that belongs to the National Atomic Energy Commission (CNEA) and it is currently placed at the Universidad Nacional de Córdoba (UNC), Argentina, was used as a neutron source 40 . The reactor normally operates at a power of 1 W. The fuel elements are vertically located in an aluminum ring structure and are composed of a mixture of UO enriched 20 % in U, graphite and pitch located inside an aluminum sheath with an active length of 54 cm, while light water is used as a neutron moderator.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The RA-0 Nuclear Reactor, a zero power reactor that belongs to the National Atomic Energy Commission (CNEA) and it is currently placed at the Universidad Nacional de Córdoba (UNC), Argentina, was used as a neutron source 40 . The reactor normally operates at a power of 1 W. The fuel elements are vertically located in an aluminum ring structure and are composed of a mixture of UO enriched 20 % in U, graphite and pitch located inside an aluminum sheath with an active length of 54 cm, while light water is used as a neutron moderator.…”
Section: Methodsmentioning
confidence: 99%
“…The samples were placed in the central irradiation channel of the reactor core. The dose absorbed by each dosimeter was calculated by means of the Monte Carlo transport code MCNP according to the procedure described elsewhere 40 . In the simulations, the contributions from photons, neutron elastic scattering and neutron absorption were discriminated so that the capture events could be quantified.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Fricke gel dosimeters were manufactured according to the method described elsewhere [23,24]. Their xylenol orange concentration was set to ppm to reduce any interference with the Ag NPs plasmonic signal.…”
Section: Fricke Gel Dosimetrymentioning
confidence: 99%
“…Surgery is usually used for initial treatment when the condition of the tumor is still in its early stages [7]. Such cancer treatment can cause side effects that occur when treatment affects tissues or healthy organs[1] [18] [19][20]. .To overcome these weaknesses BNCT has been developed with selective characteristic to cancer cells.…”
Section: Introduction mentioning