2017
DOI: 10.1039/c6ay03280j
|View full text |Cite
|
Sign up to set email alerts
|

Near-infrared fluorescence probe: BSA-protected gold nanoclusters for the detection of metronidazole and related nitroimidazole derivatives

Abstract: BSA-protected gold nanoclusters (AuNCs@BSA), as near infrared fluorescence probes, are synthesized to detect metronidazole (MTZ) and nitroimidazole derivatives, based on a photon-induced electron transfer (PET) process.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 39 publications
0
12
0
Order By: Relevance
“…But these methods need expensive instruments, complicated operations and time‐consuming sample pretreatments, which greatly limit the detection efficiency of MTZ. However, it is worth noting that fluorescent chemosensors have been increasingly applied for the detection of MTZ with high sensitivity, selectivity, and facility . Among them, organic dyes and fluorescent metal nanoclusters are the chemosensors mainly used.…”
Section: Introductionmentioning
confidence: 99%
“…But these methods need expensive instruments, complicated operations and time‐consuming sample pretreatments, which greatly limit the detection efficiency of MTZ. However, it is worth noting that fluorescent chemosensors have been increasingly applied for the detection of MTZ with high sensitivity, selectivity, and facility . Among them, organic dyes and fluorescent metal nanoclusters are the chemosensors mainly used.…”
Section: Introductionmentioning
confidence: 99%
“…Deionized water (2.5 mL) and GE [various concentrations (0-222 mg mL −1 ) for optimization, 2.5 mL] were added into the aforementioned samples, which were then sonicated for an additional 30 s for the preparation of G-BSA-AuNCs. The final mixed samples of the sonicated solutions were transferred to microwave Teflon tubes, and the microwave oven was adjusted for different reaction temperatures (50, 60, 70, 80, and 90 • C) and different reaction times (5,8,10,12,15, and 20 min), according to an optimization process. The products obtained after the microwave reactions were purified through centrifugation in a 3 K centrifugal membrane at a speed of 8000 rpm for 25 min (with an interval time of 5 min).…”
Section: Preparation and Optimization Of The Mw_bsa-aunc And Mw_g-bsamentioning
confidence: 99%
“…We optimized the synthesis conditions. The final mixtures of sonicated solutions were transferred to microwave Teflon tubes for a microwave reaction at 70 • C (100 W) for different reaction times (5,8,10,12,15, and 20 min). The obtained products were purified.…”
Section: Optimization Of the Microwave Reaction Timementioning
confidence: 99%
See 1 more Smart Citation
“…Recently, near-infrared (NIR) fluorescent probes have received much attention due to its advantages in deep tissue penetration, low background interference and minimal damage to cells and tissues [2326]. While significant advances have been made towards detecting cellular targets or small molecules with near-IR probes [2428], no such probes for Pb(II) detection in living cells were reported.…”
Section: Introductionmentioning
confidence: 99%