2020
DOI: 10.1016/j.actbio.2019.11.001
|View full text |Cite
|
Sign up to set email alerts
|

Nasolacrimal stent with shape memory as an advanced alternative to silicone products

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 15 publications
(22 citation statements)
references
References 52 publications
0
17
0
Order By: Relevance
“…The SMP, 94%polycaprolactone‐ co ‐06%poly glycidyl methacrylate (94%PCL‐06%PGMA), was synthesized using the sequential process as described previously. [ 35 ] To fabricate SES, 94%PCL‐06%PGMA was dissolved in dichloromethane (DCM; D2863, Samchun Chemical Co., Seoul, Korea) at a concentration of 100 w/v% containing 0.1 w/v% of photoinitiator (Irgacure 2959, Ciba Specialty Chemicals Inc., Basel, Switzerland). Gelatin powder (MW 50–100 kDa; Sigma‐Aldrich, St. Louis, MO, USA) was used as a porogen to generate small micropores (≈150 µm diameter).…”
Section: Methodsmentioning
confidence: 99%
“…The SMP, 94%polycaprolactone‐ co ‐06%poly glycidyl methacrylate (94%PCL‐06%PGMA), was synthesized using the sequential process as described previously. [ 35 ] To fabricate SES, 94%PCL‐06%PGMA was dissolved in dichloromethane (DCM; D2863, Samchun Chemical Co., Seoul, Korea) at a concentration of 100 w/v% containing 0.1 w/v% of photoinitiator (Irgacure 2959, Ciba Specialty Chemicals Inc., Basel, Switzerland). Gelatin powder (MW 50–100 kDa; Sigma‐Aldrich, St. Louis, MO, USA) was used as a porogen to generate small micropores (≈150 µm diameter).…”
Section: Methodsmentioning
confidence: 99%
“…10,11 We previously reported that our shape memory polymer (SMP) reduced biofilm formation by 75% compared to silicone. 12 Since then, further progress has been made to enable user-specified control of the tube diameter in the treatment of glaucoma patients. The goal of the present study is to demonstrate that a SMP tube can be programmed to enable self-expansion when inserted into the silicone tube and thereby to control small and large IOP drops before and after expansion, respectively.…”
Section: ■ Introductionmentioning
confidence: 91%
“…13,14 The shape recovery temperature (T m ) of our SMP can be controlled from 32 to 44 °C by adjusting the degree of cross-linking as reported previously. 12,15 In this study, the T m of SMP was set to 37 °C in order to prevent unexpected shape recovery in contact with the body fluid during the deployment process. The temperature of the warm saline was 39−40 °C, and the eye was exposed to this warm saline for 1 min so that the conjunctiva of the eye was warmed up to reach the T m of the SMP tube.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
See 2 more Smart Citations