2013
DOI: 10.1111/den.12075
|View full text |Cite
|
Sign up to set email alerts
|

Narrow‐band imaging with dual focus magnification in differentiating colorectal neoplasia

Abstract: Background: Real-time optical diagnosis of colorectal polyps may lead to substantial time and cost savings and could potentially reduce complications associated with polypectomy. We prospectively assessed the utility of a novel narrow-band imaging (NBI) system with dual focus magnification (DF) in differentiating colorectal polyps in consecutive patients undergoing colonoscopy. Patients and Methods:All procedures were carried out with a prototype 190 series Exera III NBI system with Dual Focus capability. Hist… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
58
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 52 publications
(59 citation statements)
references
References 14 publications
0
58
1
Order By: Relevance
“…[7][8][9][10][11][12]15,18,20,26 The pooled percentage of agreement using the random-effects model was 89% (95% CI, 85-93) (Fig. 6).…”
Section: Meta-analysis Of Nbi Studies Evaluating Npv For Adenomatous mentioning
confidence: 97%
See 1 more Smart Citation
“…[7][8][9][10][11][12]15,18,20,26 The pooled percentage of agreement using the random-effects model was 89% (95% CI, 85-93) (Fig. 6).…”
Section: Meta-analysis Of Nbi Studies Evaluating Npv For Adenomatous mentioning
confidence: 97%
“…[7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25] These studies collectively evaluated 4013 in situ small or diminutive colorectal polyps in real-time by using NBI and compared it with criterion standard histopathology. The median prevalence of adenomas among these polyps was 48.5% (range 18%-88%).…”
Section: Meta-analysis Of Nbi Studies Evaluating Npv For Adenomatous mentioning
confidence: 99%
“…17 When incorporating these features in the prediction of SSA, we found them to be acceptably accurate. Our study is the largest to date to accurately assess SSAs with the NBI-NF with a high accuracy, having been previously demonstrated by Singh et al 27 A larger study by Vu et al 28 incorporated serrated polyps into their study but did not achieve the accuracy required by the PIVI statements. Basford et al 29 achieved the PIVI requirements by using i-Scan technology (Pentax, Tokyo, Japan); however, they identified only two serrated polyps.…”
Section: Discussionmentioning
confidence: 77%
“…The main limitation of the study is that we used somewhat small numbers, which was also an issue for Singh et al 27 Our study was a proof-of-concept study to determine whether the NBI-NF can be used with confidence in detecting adenomatous pathology. This became more of an issue when we looked at subgroups such as diminutive SSAs, of which we had only 13 cases.…”
Section: Discussionmentioning
confidence: 98%
“…These have been proven to have excellent diagnostic performance, most of them achieving accuracies of greater than 90%; however, such accuracy can only be achieved by expert endoscopists. [10][11][12][21][22][23] The same is true of EC, an emerging endoscopic technology that allows real-time cellular imaging of alimentary mucosa and provides very accurate predictions of pathology (eg, accuracies of 94.1% 17 and 96.5% 25 for neoplastic change). 14,17,[24][25][26] However, with this technology as well, such accuracy is achieved only by trained and experienced expert endoscopists.…”
Section: Discussionmentioning
confidence: 99%