2021
DOI: 10.3390/ma14247851
|View full text |Cite
|
Sign up to set email alerts
|

Nanotechnology-Based Strategies for Effective and Rapid Detection of SARS-CoV-2

Abstract: The coronavirus disease 2019 (COVID-19) pandemic has gained worldwide attention and has prompted the development of innovative diagnostics, therapeutics, and vaccines to mitigate the pandemic. Diagnostic methods based on reverse transcriptase-polymerase chain reaction (RT-PCR) technology are the gold standard in the fight against COVID-19. However, this test might not be easily accessible in low-resource settings for the early detection and diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 135 publications
0
8
0
Order By: Relevance
“…However, it was found that some new techniques of QDs for SARS-CoV-2 detection could be borrowed for LFIA, thus providing excellent new options for POCT continuously. For example, a QDs method for the quantitative detection of SARS-CoV-2 IgG reported in the study by Moabelo et al has an excellent detection limit of 4 pg/ml, which is a cause for concern ( Moabelo et al, 2021 ). The method is a highly sensitive QDs-linked immunoassay based on QDs nanoparticles and magnetic iron oxide (MnFe3O4) nanomicrospheres.…”
Section: Lfia Technique For Sars-cov-2 Antibody Detectionmentioning
confidence: 99%
“…However, it was found that some new techniques of QDs for SARS-CoV-2 detection could be borrowed for LFIA, thus providing excellent new options for POCT continuously. For example, a QDs method for the quantitative detection of SARS-CoV-2 IgG reported in the study by Moabelo et al has an excellent detection limit of 4 pg/ml, which is a cause for concern ( Moabelo et al, 2021 ). The method is a highly sensitive QDs-linked immunoassay based on QDs nanoparticles and magnetic iron oxide (MnFe3O4) nanomicrospheres.…”
Section: Lfia Technique For Sars-cov-2 Antibody Detectionmentioning
confidence: 99%
“…NAATs are the gold standard diagnostic for SARS-CoV-2 infection (Tyagi et al, 2020). SARS-CoV-2 has developed many mutations that can result in immune escape (Moabelo et al, 2021). Since NAATs use nucleic acid primers to recognize and amplify their targets, the incorporation of one or more base substitutions into the targeted nucleotide sequence is potentially sufficient to inhibit the reaction.…”
Section: Therapeuticsmentioning
confidence: 99%
“…Nanosensors based on magnetic nanoparticles (MNPs) generate heat as a result of their optical properties when aggregate vibrations in energy concentration take place at the interface of nanomaterial via conjugating to magnetic radiation. The increased frequency of collisions with lattice atoms caused by the enhanced motion of conduction electrons leads to the generation of PT-induced heat (Hofmann et al 2008 ; Moabelo et al 2021 ; Esbin et al 2020 ).…”
Section: Diagnosis Of Sars-cov-2 Infestationmentioning
confidence: 99%