2021
DOI: 10.1016/j.ultsonch.2021.105718
|View full text |Cite
|
Sign up to set email alerts
|

Nanogenerator for determination of acoustic power in ultrasonic reactors

Abstract: Graphical abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 29 publications
(12 citation statements)
references
References 53 publications
0
11
0
Order By: Relevance
“…In the frequency region (ω Ob1 , ω Oa1 ), transmission coefficient t = 0 because the absolute values of the elastic coefficients of positive and negative domains are approximately equal. According to our simulation results, the two MPBGs cannot be generated in other piezoelectric phononic crystals [6][7][8][9][10]. If the SRRs are not placed on the opposite sides of the MPPC along the x-axis, the MPBGs will not also be created near the resonance frequencies.…”
Section: Discussionmentioning
confidence: 75%
See 1 more Smart Citation
“…In the frequency region (ω Ob1 , ω Oa1 ), transmission coefficient t = 0 because the absolute values of the elastic coefficients of positive and negative domains are approximately equal. According to our simulation results, the two MPBGs cannot be generated in other piezoelectric phononic crystals [6][7][8][9][10]. If the SRRs are not placed on the opposite sides of the MPPC along the x-axis, the MPBGs will not also be created near the resonance frequencies.…”
Section: Discussionmentioning
confidence: 75%
“…As a result, the phononic crystal containing a piezoelectric material known as piezoelectric phononic crystals comes to be realized and is studied widely. Vibration energy can be easily converted into electric energy by introducing piezoelectric material within the phononic crystal [6][7][8][9][10].…”
Section: Introductionmentioning
confidence: 99%
“…To check the piezoelectric output of the developed sensor, a digital oscilloscope was used and the sensor was tapped with the fingers. Silicon gloves were used to avoid any possible static charges influence [ 42 ].…”
Section: Resultsmentioning
confidence: 99%
“…Especially, we focused on current device research and application progress of piezoelectric materials in the medical field. Owing to the sensitive piezoelectric or ferroelectric properties, we further summarized the current research on perovskite piezoelectricity, and further designed and proposed its future applications in the field of ultrasound, especially the huge application prospects of ultrasound medicine applications, such as biological and chemical sensors, high-intensity focused ultrasound for medical therapeutics, blood flow rate measurement, and ultrasound imaging [40][41][42][43][44][45][46].…”
Section: Discussionmentioning
confidence: 99%