2022
DOI: 10.3390/ani12111442
|View full text |Cite
|
Sign up to set email alerts
|

Nanodelivery System for Ovsynch Protocol Improves Ovarian Response, Ovarian Blood Flow Doppler Velocities, and Hormonal Profile of Goats

Abstract: Fifteen cyclic, multiparous goats were equally stratified and received the common Ovsynch protocol (GPG: intramuscular, IM, injection of 50 mg gonadorelin, followed by an IM injection of 125 µg cloprostenol 7 days later, and a further IM injection of 50 mg gonadorelin 2 days later) or the Ovsynch protocol using nanofabricated hormones with the same dosages (NGPG) or half dosages (HNGPG) of each hormone. The ovarian structures and ovarian and luteal artery hemodynamic indices after each injection of the Ovsynch… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

7
1

Authors

Journals

citations
Cited by 22 publications
(19 citation statements)
references
References 32 publications
(48 reference statements)
0
17
0
Order By: Relevance
“…In the present study, there were marked changes in the STA Doppler indices of the CoQ10 supplemented males compared to the control group. These changes could be interpreted by a decrease in vascular resistance and higher testicular blood perfusion (Gill 1985 ; Abdelnaby et al 2022 ; Hashem et al 2022 ). It is well-known that heat-stressed males suffer lower testicular blood flow and functions (Hedia et al 2020 ).…”
Section: Discussionmentioning
confidence: 99%
“…In the present study, there were marked changes in the STA Doppler indices of the CoQ10 supplemented males compared to the control group. These changes could be interpreted by a decrease in vascular resistance and higher testicular blood perfusion (Gill 1985 ; Abdelnaby et al 2022 ; Hashem et al 2022 ). It is well-known that heat-stressed males suffer lower testicular blood flow and functions (Hedia et al 2020 ).…”
Section: Discussionmentioning
confidence: 99%
“…In addition to uterine artery crosssectional diameter was determined after color mode activation. RI was measured by an automatic equation in the device as follows RI = [PSV-EDV/PSV], while PI = [PSV-EDV/TAV], as TAV was the time average velocity to complete one cardiac cycle and EDV was the end point of velocity in the spectral graph as previously measured [35][36][37].…”
Section: Ultrasound Scanning and Doppler Analysismentioning
confidence: 99%
“…Doppler's indices (RI and PI) are good indicators of the resistance to blood flow in the examined vessel because of their negative correlations with tissue 4 Andrologia blood perfusion [38][39][40][41]. When the RI and values decrease, the resistance to the blood flow decrease [38,42,43], and this indicates an increase in the blood flow (carrying oxygen and nutrients) to the respective organ. These findings agreed with previous reports on male goats [32] and rams [13].…”
Section: Discussionmentioning
confidence: 99%