2019
DOI: 10.1007/s10876-019-01649-x
|View full text |Cite
|
Sign up to set email alerts
|

Nano Biomedical Potential of Biopolymer Chitosan-Capped Silver Nanoparticles with Special Reference to Antibacterial, Antibiofilm, Anticoagulant and Wound Dressing Material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(29 citation statements)
references
References 40 publications
0
29
0
Order By: Relevance
“…Also, Ag-ENPs have emerged as an attractive alternative approach for antimicrobial and cancer treatments. Nonetheless, their toxicological effects and low biocompatibility limited their clinical applications (Vijayakumar et al, 2020 ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, Ag-ENPs have emerged as an attractive alternative approach for antimicrobial and cancer treatments. Nonetheless, their toxicological effects and low biocompatibility limited their clinical applications (Vijayakumar et al, 2020 ).…”
Section: Resultsmentioning
confidence: 99%
“…In comparison to all the methods mentioned before, bioreduction is eco-friendly and easy to execute. Also, the Ag-ENPs obtained exhibit more excellent stability utilizing a green synthesis using methanol extract of Citrus limetta peel (Maboya et al, 2019 ); silver ions yield high biocompatible that can be handled in biomedical settings without significant adverse effects (Vijayakumar et al, 2020 ).…”
Section: Resultsmentioning
confidence: 99%
“…ZnO spectrum exhibited a UV absorption band at 360 nm, which is a characteristic absorption peak of ZnO (Ramya et al 2018). Ag exhibited a surface plasmon resonance (SPR) peak at approximately 404 nm (Das et al 2016;Vijayakumar et al 2020). However, the Ag/ZnO (5% Ag) absorption spectrum (in Figure 4(a)) was not a simple superposition of single materials spectrum.…”
Section: Photoacoustic Spectroscopy (Pas)mentioning
confidence: 99%
“…The broth microdilution technique was utilized to survey the minimum inhibitory concentration (MIC) as claimed to the Clinical and Laboratory Standards Institute (CLSI) guidelines [22]. In synopsis, Mueller Hinton broth such as twofold concentration increases of sample 6 was a xed to every well.…”
Section: -3-1-determination Of the Minimum Inhibitory Concentration mentioning
confidence: 99%