Abstract:In order to study total dose radiation effects of PbZr x Ti 1−x O 3 (PZT) film made with the pulsed excimer laser deposition (PLD) technique, hysteresis loops and capacitance-voltage (C-V ) curves of PZT film capacitors have been measured before and after γ -ray irradiation. The results show that, in a range of 0-2 × 10 5 Gy (Si), with increasing total dose, the remanent polarization 2P r increased while dielectric constant ε decreased. This can be explained by charges trapped by some defects during irradiatio… Show more
“…Alternatively, the measurement has been expanded into the two-dimensional (2D) space recently. [38][39][40][41] It is, however, still difficult to measure the rapid and minute velocity components in the heart wall by these methods. For thorough analysis of the propagation of the minute mechanical-excitation wave-front, the heart wall velocity distribution should be measured in the 2D space with high temporal and spatial resolutions.…”
Additions to the Spectra Lila, Lizb and LiZla.Six new spectral lines have been observed in the lithium spectrum between 200 nm and 600 nm. Possible classifications are given and discussed.
“…Alternatively, the measurement has been expanded into the two-dimensional (2D) space recently. [38][39][40][41] It is, however, still difficult to measure the rapid and minute velocity components in the heart wall by these methods. For thorough analysis of the propagation of the minute mechanical-excitation wave-front, the heart wall velocity distribution should be measured in the 2D space with high temporal and spatial resolutions.…”
Additions to the Spectra Lila, Lizb and LiZla.Six new spectral lines have been observed in the lithium spectrum between 200 nm and 600 nm. Possible classifications are given and discussed.
“…The moving-averagefilter window is W a ¼ 3:5 mm, the same size as that used in our previous studies. [27][28][29] The numbers of elements in the radial and circumferential directions are 80 and 256, respectively. The optimized pseudo elasticity parameters are set in the range of 20 to 2800 in the radial direction and 20 to 800 in the shear direction from the results of preliminary experiments as mentioned in §2.1.…”
The accurate assessment of local myocardial strain is important for diagnosing ischemic heart diseases because decreased myocardial motion often appears in the early stage. Calculating the spatial derivation of displacement is a necessary step in the strain calculation, but the numerical calculation is extremely sensitive to noise. Commonly used smoothing methods are the moving-average and median filters; however, these methods have a trade-off between spatial resolution and accuracy. A novel smoothing/fitting method is proposed for overcoming this problem. In this method, the detected displacement vectors are discretized at mesh nodes, and virtual springs are connected between adjacent nodes. By controlling the elasticity of the virtual springs, misdetected displacements are fitted without the above problem. Further improvements can be achieved by applying a Kalman filter for position tracking, and then calculating the strain from the accumulated displacement vectors. From the simulation results, we conclude that the proposed method improves the accuracy and spatial resolution of the strain images. #
“…In these simulations, the RF signals with a signal-to-noise ratio (SNR) of 20 dB are digitized at a rate of 20 MHz. The median filter's window size and averaging filter's window size are the same as our pervious researches (16)- (18) , and their values are W m = 3.5 mm and W a = 3.5 mm, respectively. The element numbers in the radial direction are 80, and 256 in the circumferential direction.…”
Section: Simulation Conditionsmentioning
confidence: 99%
“…Hence, it is not convenient and the processing speed is not fast. In order to solve the above problems, a myocardial strain imaging system based on the combined autocorrelation method (CAM) (13) and the 3-D weighted phase gradient method (WPGM) (14) (15) , which can detect all directions' true displacement vectors, has been proposed previously (16)- (18) . In this research, in order to obtain a more accurate phase-shift, a new method which incorporates an extended combined autocorrelation method (ECAM) (19) (20) into the WPGM is proposed.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.