Multizone modelling of a hybrid ventilated high-rise building based on full-scale measurements for predictive control

Abstract: Hybrid ventilation is an effective approach to reduce cooling energy consumption by combining natural and mechanical ventilation. Previous studies of full-scale whole-building measurements of high-rise hybrid ventilation are quite limited due to the complexities of buildings and variable ambient conditions. As a result, validated and accurate whole-building simulations of hybrid ventilation often cannot be found in the literature. This paper reports a series of full-scale measurements of hybrid ventilation in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 26 publications
0
7
0
Order By: Relevance
“…Turbulent diffusion and complex vortex structure caused the non-uniform distribution of air pollutant. Occupants in rooms of the upstream building may suffer from serious airborne pollution, due to natural ventilation or envelope infiltration ( Ng et al, 2019 ; Qi, Cheng, Katal, Wang, & Athienitis, 2019 ). In courtyard environment, outdoor spaces near the upstream building should be controlled by some artificial measures (e.g.…”
Section: Resultsmentioning
confidence: 99%
“…Turbulent diffusion and complex vortex structure caused the non-uniform distribution of air pollutant. Occupants in rooms of the upstream building may suffer from serious airborne pollution, due to natural ventilation or envelope infiltration ( Ng et al, 2019 ; Qi, Cheng, Katal, Wang, & Athienitis, 2019 ). In courtyard environment, outdoor spaces near the upstream building should be controlled by some artificial measures (e.g.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, a realtime infiltration-rate-based ventilation control strategy has been proposed and evaluated. 12 Hybrid ventilation is an effective approach to reduce cooling energy consumption by combining natural and mechanical ventilation in high-rise buildings. However, most of the previous studies of full-scale whole-building measurements of high-rise hybrid ventilation are quite limited due to complexities of buildings and variable ambient conditions.…”
Section: New and Emerging Building Ventilation Technologiesmentioning
confidence: 99%
“…Based on full-scale measurements of hybrid ventilation, a simplified multizone model has been proposed and a case study of whole-building simulations for a 17storey institutional building was performed. 12 • Novel simulation method. Inhalation exposure to indoor particulate contaminants is one of the leading threats to public health.…”
Section: New and Emerging Building Ventilation Technologiesmentioning
confidence: 99%
“…Multizone airflow models have been widely used in analysis of pressure difference, airflow, and pollutant between different rooms [ 35 , 36 ]. The multizone airflow model in CONTAM is a macro model that ignores details of rooms when calculating the pressure and air volume, it is assumed that the air in the area is well-mixed and the parameters are uniform [25] .…”
Section: Methodsmentioning
confidence: 99%