2011
DOI: 10.1016/j.bios.2011.08.010
|View full text |Cite
|
Sign up to set email alerts
|

Multiwalled carbon nanotubes dispersed in carminic acid for the development of catalase based biosensor for selective amperometric determination of H2O2 and iodate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
19
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 71 publications
(21 citation statements)
references
References 44 publications
2
19
0
Order By: Relevance
“…There is also a clear signal at wavenumber 900 cm −1 due to bending vibrations of OH groups from carboxyl group. All of these data are in agreement with the literature [6,15,19]. …”
Section: Resultssupporting
confidence: 93%
See 1 more Smart Citation
“…There is also a clear signal at wavenumber 900 cm −1 due to bending vibrations of OH groups from carboxyl group. All of these data are in agreement with the literature [6,15,19]. …”
Section: Resultssupporting
confidence: 93%
“…Carmine has also many biological applications: it can prevent coronary artery disease [11], it plays a role in treating Alzheimer’s disease [12], it exhibits cancer chemopreventive activity, [13] and is used in drug delivery products [14]. There exist a few publications concerning the adsorption of carmine or carminic acid, and they relate exclusively to inorganic adsorbents: TiO 2 [15], glass beads [16], Amberlite XAD-16 resin [9], Ag nanoparticles [17], methacrylic acid (MAA) and 4-vinylpyridine [18], and multiwalled carbon nanotubes [19]. Carmine or carminic acid have also been combined with SiO 2 sol-gel glass [8], hydrotalcite [20], and amorphous SiO 2 [21].…”
Section: Introductionmentioning
confidence: 99%
“…The maximum of anodic current occurred at pH 7.0. This value was consistent with that reported for catalase enzyme [60, 7678]. Based on these results, pH 7.0 for PBS buffer solution was used as the optimal pH for further experiments.…”
Section: Resultssupporting
confidence: 90%
“…The advantages of electrochemical methods, such as sensitivity, selectivity, facile, high performance, low cost, high accuracy and precision, aroused the attention of many researchers. 1,5,35,[41][42][43][44][45][46][47][48][49][50][51] Other methods such as immunoassay kits and chromatographic methods require sample preparation that consumes a long time, are expensive and necessitate the use environmentally hazardous solvents. 1,5,35 In the present work, we applied a carbon nanotubes-modified graphite paste electrode for determination of HCy using dopamine (DP) as an electrocatalytic mediator.…”
Section: Introductionmentioning
confidence: 99%