2010
DOI: 10.2116/analsci.26.853
|View full text |Cite
|
Sign up to set email alerts
|

Multivariate Optimization and Validation of a Capillary Electrophoresis Method for the Simultaneous Determination of Dextromethorphan Hydrobromur, Phenylephrine Hydrochloride, Paracetamol and Chlorpheniramine Maleate in a Pharmaceutical Preparation Using Response Surface Methodology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 21 publications
(13 citation statements)
references
References 10 publications
(7 reference statements)
0
13
0
Order By: Relevance
“…EM ¼ 552:2465 À 30:2713x 1 þ 23:8576x 2 þ 158:2195x 3 À 55:2079x 2 1 À 19:2924x 2 2 À 2:5382x 2 3 À 4:9225x 1 x 2 À 4:7425x 2 x 3 À 13:58x 1 x 3 for DOR, EM ¼ 593:8379 þ 15:6577x 1 þ 29:1601x 2 þ 183:614x 3 À 44:5411x 2 1 À 16:6017x 2 2 þ 5:3649x 2 3 À 3:4113x 1 x 2 À 3:1788x 2 x 3 þ 3:7963x 1 x 3 for TIM; By use of these equations containing coefficients, the value of the third factor was calculated to provide the optimum experimental conditions when the other two factors were known [3].…”
Section: Response-surface Methodology For Multivariate Optimizationmentioning
confidence: 99%
See 1 more Smart Citation
“…EM ¼ 552:2465 À 30:2713x 1 þ 23:8576x 2 þ 158:2195x 3 À 55:2079x 2 1 À 19:2924x 2 2 À 2:5382x 2 3 À 4:9225x 1 x 2 À 4:7425x 2 x 3 À 13:58x 1 x 3 for DOR, EM ¼ 593:8379 þ 15:6577x 1 þ 29:1601x 2 þ 183:614x 3 À 44:5411x 2 1 À 16:6017x 2 2 þ 5:3649x 2 3 À 3:4113x 1 x 2 À 3:1788x 2 x 3 þ 3:7963x 1 x 3 for TIM; By use of these equations containing coefficients, the value of the third factor was calculated to provide the optimum experimental conditions when the other two factors were known [3].…”
Section: Response-surface Methodology For Multivariate Optimizationmentioning
confidence: 99%
“…In addition to chromatographic techniques, capillary electrophoresis has been widely used in recent decades for resolving mixtures and has been used for analysis of multi-component samples with remarkable advantages, for example low sample volume, consumption of small amounts of running buffer, large theoretical plate number, wide working range, and low expense [3].…”
Section: Introductionmentioning
confidence: 99%
“…Phenylephrine hydrochloride (PHE), (R)‐2‐methylamino‐1‐3(‐hydroxyphenyl)ethanol hydrochloride (Figure c) is a widely applied effective sympathomimetic agent that has vasoconstrictor effects and is used as a nasal decongestant to relieve severe cold symptoms . Various analytical methods have been reported for the quantitation of PHE in different pharmaceutical forms using spectrophotometric methods, spectrofluorometric methods, HPLC, electrochemical analysis and CE …”
Section: Introductionmentioning
confidence: 99%
“…It is used mainly as a nasal decongestant either alone or in combination with other agents for the symptomatic relief of cold symptoms . PHE has been previously determined in several pharmaceutical forms using HPLC , CE , spectrophotometry , spectrofluorimetry and electrochemical analysis .…”
Section: Introductionmentioning
confidence: 99%