2018
DOI: 10.1016/j.talanta.2018.07.017
|View full text |Cite
|
Sign up to set email alerts
|

Multivariate curve resolution strategy for non-quadrilinear type 4 third-order/four way liquid chromatography–excitation-emission fluorescence matrix data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 27 publications
0
5
0
1
Order By: Relevance
“…124,125 Por último, en un tercer enfoque se propuso el acoplamiento del instrumento cromatográfico a un espectrofotómetro de fluorescencia de barrido rápido, conectando el capilar de salida de la columna de separación a una celda de flujo ubicada en el porta-cubetas del espectrofotómetro. 126,127,128 El correcto modelado de los datos generados es esencial para lograr extraer mayor información de calidad y representativa del caso real de estudio. Para ello, se han aplicado diferentes algoritmos de segundo y tercer orden.…”
Section: Consideraciones Generalesunclassified
“…124,125 Por último, en un tercer enfoque se propuso el acoplamiento del instrumento cromatográfico a un espectrofotómetro de fluorescencia de barrido rápido, conectando el capilar de salida de la columna de separación a una celda de flujo ubicada en el porta-cubetas del espectrofotómetro. 126,127,128 El correcto modelado de los datos generados es esencial para lograr extraer mayor información de calidad y representativa del caso real de estudio. Para ello, se han aplicado diferentes algoritmos de segundo y tercer orden.…”
Section: Consideraciones Generalesunclassified
“…This phenomenon occurs as a consequence of the lag between the elution and the fluorescence scanning rates. To cope with these limitations, researchers have implemented novel instrumental configurations [26], developed new spectrometers [27] and introduced new chemometric alternatives [28]. Escandar's group implemented a chromatographic setup that decreased the time dependence effect by reducing the linear flow rate of the mobile phase, incorporating a large inner-diameter tube between the column and the flow-cell [26].…”
Section: Third-order Datamentioning
confidence: 99%
“…LODs: 1.0-1.4 ng mL −1 (validation samples). LODs: 1.3-2.9 ng mL −1 (samples with interferents) [28] Pipemidic acid, marbofloxacin, enoxacin, ofloxacin, norfloxacin, ciprofloxacin, lomefloxacin, danofloxacin, enrofloxacin, sarafloxacin (quinolone antibiotics) in animal tissues (chicken liver, bovine liver and kidney)…”
Section: Third-order/four-way Chromatographic Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…In some cases, a preprocessing oriented approach is proposed to correct for the lack of fulfillment of the trilinear model, for instance in the case of peak misalignments of the profiles of the same component in the different simultaneously analyzed datasets, 2D warping methodologies or similar methods have been proposed [ 23 , 24 ]. In some other situations, like in liquid chromatography, peak shape changes can occur when strong coelutions are present [ 25 , 26 , 27 , 28 , 29 ]. In these situations, the strict trilinear model is not valid and the data resolution with these methods produces unique profiles far from the true profiles.…”
Section: Introductionmentioning
confidence: 99%