The inclusional complexation between the anti-inflammatory pharmaceutical diclofenac and beta-cyclodextrin (beta-CD) was studied by potentiometry, spectrophotometry and spectrofluorimetry, in both acid and neutral pH. Guest-host 1:1 stoichiometries for the complexes in both media were determined, and their equilibrium constants were calculated. The values obtained from the different methods used are in very good agreement and are in the order of 10(3). From the analysis of the pKa value for diclofenac in both the absence and presence of beta-CD (4.84 and 4.90 respectively), it was inferred that in the inclusion complex the carboxylic group is located outside the cavity. Further structural characterization of the inclusate was carried out by means of 1H NMR spectra and AM1 semiempirical calculations. Based on the obtained results, a spectrofluorimetric method for the determination of diclofenac in the presence of beta-CD was developed in the range of 0-5 micrograms ml-1. Better limits of detection (0.03 microgram ml-1) and quantification (0.1 microgram ml-1) were obtained in this latter case with respect to those obtained in the absence of beta-CD. The method was satisfactorily applied to the quantification of diclofenac in pharmaceutical preparations.
Four-way fluorescence data recorded by following the kinetic evolution of excitation-emission fluorescence matrices (EEMs) have been analyzed by parallel factor analysis and trilinear least-squares algorithms. These methodologies exploit the second-order advantage of the studied data, allowing analyte concentrations to be estimated even in the presence of an uncalibrated fluorescent background. They were applied to the simultaneous determination of the components of the anticancer combination of methotrexate and leucovorin in human urine samples. Both analytes were converted into highly fluorescent compounds by oxidation with potassium permanganate, and the kinetics of the reaction was continuously monitored by recording full EEM of the samples at different reaction times. A commercial fast scanning spectrofluorometer has been used for the first time to measure the four-way EEM kinetic data. The rapid scanning instrument allows the acquisition of a complete EEM in 12 s at a wavelength scanning speed of 24 000 nm/min. The emission spectra were recorded from 335 to 490 nm at 5-nm intervals, exciting from 255 to 315 nm at 6-nm intervals. Ten successive EEMs were measured at 72-s intervals, to follow the fluorescence kinetic evolution of the mixture components. Good recoveries were obtained in synthetic binary samples and also in spiked urine samples. The excitation, emission, and kinetic time profiles recovered by both chemometric techniques are in good agreement with experimental observations.
This work presents a novel approach for the simultaneous ultratrace determination of benzo[ a]pyrene and dibenzo[ a,h]anthracene, the two most carcinogenic polycyclic aromatic hydrocarbons (PAHs), in a very interfering environment, combining the recently discovered ability of the nylon membrane to strongly retain and concentrate PAHs on its surface, the sensitivity of molecular fluorescence, and the selectivity of second-order chemometric algorithms. The fluorescence excitation-emission matrices, directly measured on a nylon-membrane surface, are processed by applying parallel factor analysis (PARAFAC) and unfolded partial least-squares coupled to residual bilinearization (U-PLS/RBL). The superiority of U-PLS/RBL to quantify BaP and DBA at concentrations below 10 ng L (-1) in the presence of the remaining 14 US EPA (United States Environmental Protection Agency) PAHs at total concentrations ranging from 1400 and 14,000 ng L (-1) is demonstrated. The present method successfully faces this complex challenge without using organic solvents, which are to known produce environmental contamination. Finally, the high sensitivity of the present method avoids preconcentration and elution steps, considerably decreasing the analysis time and the experimental errors. Because the instrumental involved in the determination is nonsophisticated, the experiments could be carried out in routine laboratories.
Multivariate calibration coupled to high-performance liquid chromatography-fast scanning fluorescence spectroscopy (HPLC-FSFS) was employed for the analysis of 10 selected polycyclic aromatic hydrocarbons (PAHs), six of which correspond to heavy PAHs. The goal of the present study was the successful resolution of a system even in the presence of real interferences. Second-order HPLC-FSFS data matrices were obtained in a short time with a chromatographic system operating in isocratic mode. The difficulties in aligning chromatographic bands in complex systems, such as the ones presented here, are discussed. Two second-order calibration algorithms which do not require chromatographic alignment were selected for data processing, namely, multivariate curve resolution-alternating least-squares (MCR-ALS) and parallel factor analysis 2 (PARAFAC2). These algorithms did also achieve the second-order advantage, and therefore they were able to overcome the problem of the presence of unexpected interferences. The study was employed for the discussion of the scopes of the applied second-order chemometric tools, demonstrating the superiority of MCR-ALS to successfully resolve this complex system. The quality of the proposed techniques was assessed on the basis of the analytical recoveries from different types of water and olive oil samples after solid-phase extraction. The studied concentration ranges in water samples were 5.6 x 10(-3)-0.20 ng mL(-1) for heavy PAHs and 0.036-0.80 ng mL(-1) for light PAHs, while in oil samples the PAHs concentrations were 0.13-9.6 and 2.3-49.5 ng mL(-1) for heavy and light PAHS, respectively. All real samples were analyzed in the presence of the studied interferences.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.