2002
DOI: 10.1016/s0021-9673(02)01409-7
|View full text |Cite
|
Sign up to set email alerts
|

MultiSimplex optimisation of the solid-phase microextraction–gas chromatographic–mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
38
0
1

Year Published

2003
2003
2014
2014

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 94 publications
(40 citation statements)
references
References 13 publications
1
38
0
1
Order By: Relevance
“…Several analytical methods have been developed for determining PAEs by gas chromatography (GC) [7,8], high performance liquid chromatography (HPLC) [9,10] using different preconcentration techniques such as liquid-liquid extraction (LLE) [11], solid-phase microextraction (SPME) [12,13] and solid-phase extraction (SPE) [14][15][16][17] in several types of matrices. Among above-mentioned sample pretreatment procedures, solid-phase extraction based on different types of sorbents such as C 8 [15], organic polymers [16] was widely used.…”
Section: Introductionmentioning
confidence: 99%
“…Several analytical methods have been developed for determining PAEs by gas chromatography (GC) [7,8], high performance liquid chromatography (HPLC) [9,10] using different preconcentration techniques such as liquid-liquid extraction (LLE) [11], solid-phase microextraction (SPME) [12,13] and solid-phase extraction (SPE) [14][15][16][17] in several types of matrices. Among above-mentioned sample pretreatment procedures, solid-phase extraction based on different types of sorbents such as C 8 [15], organic polymers [16] was widely used.…”
Section: Introductionmentioning
confidence: 99%
“…Razaei et al (Rezaei et al 2008) tried DLLME with 500 μL acetone as dispersive solvent and 10.0 μL of chlorobenzene as extraction solvent for 5 ml of PCBs spiked water sample. LoD values of this procedure was improved compared to previously described SPME (Cortazar et al 2002), SDME (Lambropoulou et al 2007) and MASE (McFarland et al1989) Sample preparation for PAHs analysis Two ISO sample preparation procedures (ISO 17993:2002 andISO 28540:2011) based on LLE with hexane are commonly used for PAHs analysis by GC and HPLC techniques. In both cases, one liter of water sample is dechlorinated with of sodium thiosulfate, and pH of water is adjusted to value 2 with sodium thiosulfate for HPLC analysis.…”
Section: Sample Preparation Procedures For Organochlorinated Pollutantsmentioning
confidence: 98%
“…In general, LoDs of the determined compounds were higher than the recommended values by ISO procedure, but the improved recoveries (83-103 %) were obtained with DLLME-SFO procedure. As to PCBS the PDMS fibre (30 μm film coating) was used for concentration of the congeners from water sample in presence of PAHs and phthalate esters (Cortazar et al 2002). In this case, a larger amount of water sample was required for extraction, but much worse LoD values were received compared to the other similar investigations.…”
Section: Sample Preparation Procedures For Organochlorinated Pollutantsmentioning
confidence: 99%
“…Ftalati su se u dosadašnjim znanstvenim istraživanjima zbog migracije određivali u vodi (45)(46)(47), ambalažnom materijalu (8), PVC igračkama (48), bezalkoholnim pićima i mineralnoj vodi (49) te u ljudskom mlijeku (50), urinu (51) i serumu (52).…”
Section: Migracija Ftalata I Zakonska Regulativaunclassified