2009
DOI: 10.1021/ac901853g
|View full text |Cite
|
Sign up to set email alerts
|

Multiplexed Determination of Protein Biomarkers Using Metal-Tagged Antibodies and Size Exclusion Chromatography−Inductively Coupled Plasma Mass Spectrometry

Abstract: A liquid-phase immunoassay was developed for the simultaneous determination of five cancer biomarker proteins: alpha-fetoprotein (AFP), human chorionic gonadotropin (hCG), carcinoembryonic antigen (CEA), ovarian tumor antigen (CA125/MUC16), and gastrointestinal tumor antigen (CA19-9). The method was based on the incubation of a serum (or tissue cytosol) with five antibodies, each labeled with a different lanthanide (Pr(3+), Eu(3+), Gd(3+), Ho(3+), and Tb(3+), respectively) followed by the specific determinatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
75
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 87 publications
(77 citation statements)
references
References 38 publications
(73 reference statements)
2
75
0
Order By: Relevance
“…Table 3 shows the comparison of the proposed method with other methods for the analysis of AFP and CEA. It can be seen that the established method exhibited lower or comparable LODs than that obtained by other ICP-MS based immunoassay method [20,37,35,38] and higher than that obtained by the ICP-MS-based method involving single particle detection mode [23]. Besides, the established magnetic immunoassay method allowed simultaneous determination of AFP and CEA and showed higher sensitivity over chemiluminescent immunoassay.…”
Section: Analytical Performancementioning
confidence: 78%
“…Table 3 shows the comparison of the proposed method with other methods for the analysis of AFP and CEA. It can be seen that the established method exhibited lower or comparable LODs than that obtained by other ICP-MS based immunoassay method [20,37,35,38] and higher than that obtained by the ICP-MS-based method involving single particle detection mode [23]. Besides, the established magnetic immunoassay method allowed simultaneous determination of AFP and CEA and showed higher sensitivity over chemiluminescent immunoassay.…”
Section: Analytical Performancementioning
confidence: 78%
“…This LOD value was far below the threshold of CEA (2.5 ng/ml) in normal human serum [32]. It was also below the LOD values obtained from inductively coupled plasma mass spectrometry (0.14 ng/ml) [33], capillary-based three-dimensional immunosensor (0.2 ng/ml) [34], size exclusion chromatography with inductively coupled plasma mass spectrometric detection (2.6 ng/ml) [35], rolling circle amplification for protein detection (6.8×10 −12 M) [11], and isothermal circular strand-displacement polymerization for protein detection (12 ng/ml) [13]. Assay reproducibility was estimated by analyzing a standard solution of CEA at 5.0 ng/ml (n=7).…”
Section: Resultsmentioning
confidence: 99%
“…β-Diketonate ligands coordinate via the two oxygen atoms leading to neutral species in a 3:1 β-diketonate:lanthanide ratio, the complexes have been shown to be stable in aqueous solutions [35]. Therefore these molecules have been used in many applications from sensing [36], antibody labeling [37], new materials such as liquid crystals [38], near IR-LEDs, [39] sol-gel glasses [40], and polymers [40]. …”
Section: Resultsmentioning
confidence: 99%