2019
DOI: 10.1172/jci122390
|View full text |Cite
|
Sign up to set email alerts
|

Multiple stimulation parameters influence efficacy of deep brain stimulation in parkinsonian mice

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

6
28
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(34 citation statements)
references
References 27 publications
(32 reference statements)
6
28
0
Order By: Relevance
“…This is in line with previous studies 44 and thought to result from the supersensitivity of ERK signaling in the 6-OHDA-lesioned hemisphere 45 . Our DBS results mirror a recent study in 6-OHDA-lesioned mice 22 , reporting improved locomotion with no effect on rotational bias. Surprisingly, DBS in mice does not recapitulate the typical motor improvements observed in rats 8,46,47 , although results in rats also vary depending on the intensity and the duration of stimulation [48][49][50] .…”
Section: Discussionsupporting
confidence: 89%
See 2 more Smart Citations
“…This is in line with previous studies 44 and thought to result from the supersensitivity of ERK signaling in the 6-OHDA-lesioned hemisphere 45 . Our DBS results mirror a recent study in 6-OHDA-lesioned mice 22 , reporting improved locomotion with no effect on rotational bias. Surprisingly, DBS in mice does not recapitulate the typical motor improvements observed in rats 8,46,47 , although results in rats also vary depending on the intensity and the duration of stimulation [48][49][50] .…”
Section: Discussionsupporting
confidence: 89%
“…4e) but increased the locomotor activity (p = 0.0438; Fig. 5f), in line with a recent report 22 . DBS did not modify asymmetrical locomotor behavior for the cylinder test (n = 12, p = 0.9768; Fig.…”
Section: Dbs Decreases Pathological Hyperactivity Of Pyramidal Cellssupporting
confidence: 93%
See 1 more Smart Citation
“…Despite the key role that DBS amplitude plays in DBS calibration procedures, multiple surveys have shown that only fine-tuning the amplitude can lead to side effects such as gait problems, movement interruption and speech impairments ( Törnqvist et al, 2005 ; Moreau et al, 2008 ; Tommasi et al, 2008 ; Xie et al, 2012 ; Tripoliti et al, 2014 ; Dayal et al, 2017 ). It has been reported that the total electrical energy delivered (TEED) has a significant impact on STN-DBS treatments ( Schor and Nelson, 2019 ). TEED can be calculated as follows:…”
Section: Discussionmentioning
confidence: 99%
“…where I is the current amplitude, f stimulation frequency, PW pulse-width and Z is the electrode-tissue impedance. A study by Schor and Nelson (2019) has reported that the current amplitude has a linear effect on hemi-PD mice’s movement velocities. Our finding also corroborates a strong linear relationship between the amplitude and all the three features we defined (rotation, area under the curve, and total distance).…”
Section: Discussionmentioning
confidence: 99%