1995
DOI: 10.1103/physrevb.52.2995
|View full text |Cite
|
Sign up to set email alerts
|

Multiple-scattering calculations of x-ray-absorption spectra

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

14
1,906
0
7

Year Published

1999
1999
2017
2017

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 2,778 publications
(1,927 citation statements)
references
References 49 publications
14
1,906
0
7
Order By: Relevance
“…The energy range of XAFS was calibrated using Zn and Ni foils at 9659 and 8333 eV. The EXAFS data has been examined using FEFF 6.0 code 22 , which comprises Fourier transform with background reduction to derive the versus R spectra from the absorption spectra using ATHENA software, generation of the theoretical EXAFS spectra starting from a presumed crystallographic structure and lastly fitting of experimental data with the theoretical spectra using ARTEMIS software 23 . Room temperature fluorescence spectroscopic measurement was conducted using a spectrofluorometer having …”
Section: Methodsmentioning
confidence: 99%
“…The energy range of XAFS was calibrated using Zn and Ni foils at 9659 and 8333 eV. The EXAFS data has been examined using FEFF 6.0 code 22 , which comprises Fourier transform with background reduction to derive the versus R spectra from the absorption spectra using ATHENA software, generation of the theoretical EXAFS spectra starting from a presumed crystallographic structure and lastly fitting of experimental data with the theoretical spectra using ARTEMIS software 23 . Room temperature fluorescence spectroscopic measurement was conducted using a spectrofluorometer having …”
Section: Methodsmentioning
confidence: 99%
“…29 For 55 recording the spectrum of the tin(II) containing solutions, 15 mL sample was placed in a cubic polyethylene sample holder with a tightly fitted screw-top. The analysis of the data was performed with the EXAFSPAK 30 and FEFF 31 program packages allowing the determination of the structure parameters of the local 60 coordination around tin(II).…”
Section: X-ray Absorption Measurementsmentioning
confidence: 99%
“…Final fits generally allowed only five unconstrained variables from a total of fourteen parameters. Photoelectron scattering amplitudes and phase shifts were calculated using the FEFF7 code 54 28 Aliquots of 0.450 mL each were retrieved after each DCl addition. 1 H NMR spectra of each aliquot were performed on a Brucker Avance AV-500 MHz equipped with a TBI probe, using a pulse angle of 90° and 128 scans per sample.…”
Section: Dft Calculationsmentioning
confidence: 99%