1995
DOI: 10.1016/0003-2670(94)00281-p
|View full text |Cite
|
Sign up to set email alerts
|

Multicommutation in flow analysis. Part 2. Binary sampling for spectrophotometric determination of nickel, iron and chromium in steel alloys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0
1

Year Published

1996
1996
2008
2008

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 52 publications
(11 citation statements)
references
References 13 publications
0
10
0
1
Order By: Relevance
“…The flow set up consisted of a 432 Femto (São Paulo, Brasil) spectrophotometer with a flow cell (180 µL inner volume, 12 mm optical path), coupled to a REC 61 Radiometer strip chart recorder, an Ismatec IPC-8 peristaltic pump, with Tygon pumping tubes of different inner diameters, a home made automatic injector designed as described in the next section, three-way solenoid valves 5 , coiled reactors and flow lines of polyethylene tubing (0.8 mm inner diameter), a resin column (10 mm long, 4 mm i.d) machined in perspex as described elsewhere 12 , a 486 microcomputer equipped with an interface PCL-771S Advantech Corp. and other needful electronic interface 5 . The microcomputer run a software written in Quick Basic 4.5, which controlled injector and solenoid valves.…”
Section: Apparatusmentioning
confidence: 99%
See 2 more Smart Citations
“…The flow set up consisted of a 432 Femto (São Paulo, Brasil) spectrophotometer with a flow cell (180 µL inner volume, 12 mm optical path), coupled to a REC 61 Radiometer strip chart recorder, an Ismatec IPC-8 peristaltic pump, with Tygon pumping tubes of different inner diameters, a home made automatic injector designed as described in the next section, three-way solenoid valves 5 , coiled reactors and flow lines of polyethylene tubing (0.8 mm inner diameter), a resin column (10 mm long, 4 mm i.d) machined in perspex as described elsewhere 12 , a 486 microcomputer equipped with an interface PCL-771S Advantech Corp. and other needful electronic interface 5 . The microcomputer run a software written in Quick Basic 4.5, which controlled injector and solenoid valves.…”
Section: Apparatusmentioning
confidence: 99%
“…After several analytical cycles, chloride concentration became high enough to cause competition with peroxydisulphate ions by resin active sites. As a result, a drop in analytical signal was observed, since the kinetics of the chemical reaction depends strongly on peroxydisulphate concentration 5 . In order to prevent this drawback, peroxydisulphate solution was changed after that number of analytical cycles.…”
Section: Nickel Determinationmentioning
confidence: 99%
See 1 more Smart Citation
“…This drawback has been surmounted by designing flow systems based on merging zones [2,3] or on sandwich-technique approaches [4]. When analytes compound absorb radiation at the same wavelengths, the flow networks have been designed to determine each analyte at a different time [5]. On the other hand, if chemical species absorb at a different wavelength, simultaneous determination had been carried out, nevertheless equipment with the ability to sweep automatically the wavelengths have been employed [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…Afterwards, a large number of flow procedures for multiparameter determination per sample using different detection techniques have been described [2][3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%