Multicentre evaluation of the Boehringer Mannheim/Hitachi 911 Analysis System

Abstract: The analytical performance and practicability of the Boehringer Mannheim (BM)/Hitachi 911 analysis system have been assessed in a multicentre evaluation, which involved six laboratories from European countries. Analytes commonly used in classical clinical chemistry were tested in a core programme, which mainly followed the ECCLS guidelines. In addition, a satellite programme covered other analytes, such as proteins, drugs and urine analytes. In total, the study comprised more than 100 000 data items collected … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0
1

Year Published

2000
2000
2015
2015

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 3 publications
0
4
0
1
Order By: Relevance
“…Blood samples were collected at rest from a forearm antecubital vein by a trained phlebotomist. Pre- and post-altitude iron parameters (serum ferritin and TSAT) were measured at the AIS using either a Hitachi 911 (Boehringer, GmbH, Mannaheim, Ingelheim, Germany) or a COBAS Integra 400 (Roche Diagnostics, Switzerland) via immunoturbidimetry [ 23 ], with the same analyser always used for each pre versus post comparison.…”
Section: Methodsmentioning
confidence: 99%
“…Blood samples were collected at rest from a forearm antecubital vein by a trained phlebotomist. Pre- and post-altitude iron parameters (serum ferritin and TSAT) were measured at the AIS using either a Hitachi 911 (Boehringer, GmbH, Mannaheim, Ingelheim, Germany) or a COBAS Integra 400 (Roche Diagnostics, Switzerland) via immunoturbidimetry [ 23 ], with the same analyser always used for each pre versus post comparison.…”
Section: Methodsmentioning
confidence: 99%
“…Anschließend wird die Messzelle durch die interne Referenzlösung gewaschen. Je nach Anforderung werden die Analysedaten einzeln oder hintereinander vom Hitachi 911 gesendet und dann über die Kontrolleinheit zum Drucken gegeben(HOLCAK & RIEHS, 2003;ZAMAN et al 1993). Die Objektträger wurden nach Angaben des Herstellers mit demBlutausstrichfärbeautomat vonHema-Tek (Bayer, Leverkusen, Germany) vorgenommen.…”
unclassified
“…The interference results are given in table 8, clearly showing that also for the BM/Hitachi 917 interference exists sometimes, as could be expected because of the chemistries applied. It is a situation that can be found in equivalent analysers as well [2].…”
Section: Discussionmentioning
confidence: 97%