2018
DOI: 10.1049/iet-smt.2017.0096
|View full text |Cite
|
Sign up to set email alerts
|

Multi‐resonant FLL‐based control algorithm for grid interfaced multi‐functional solar energy conversion system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 18 publications
0
11
0
Order By: Relevance
“…For metaheuristic optimization algorithms, the selection of heuristic coefficient is critical [9,10]. In this research, a separate study of the influence of the heuristic coefficients was not carried out.…”
Section: Swarm Intelligence Applicationmentioning
confidence: 99%
See 1 more Smart Citation
“…For metaheuristic optimization algorithms, the selection of heuristic coefficient is critical [9,10]. In this research, a separate study of the influence of the heuristic coefficients was not carried out.…”
Section: Swarm Intelligence Applicationmentioning
confidence: 99%
“…Such practices include metaheuristic stochastic methods. Much modern research has been devoted to optimal control in smart grid networks with distributed generation and renewable energy sources [7][8][9]. However, the optimal control is carried out at the level of a supersystem in them, and not individual GC.…”
Section: Introductionmentioning
confidence: 99%
“…These in-phase unit templates (w pa , w pb , w pc ) and quadrature unit templates (w qa , w qb , w qc ) are then multiplied with their corresponding active source currents component to estimate reference generator currents i sa * = I pLT * w pa + I qLT * w qa (11) i sb * = I pLT * w pb + I qLT * w qb (12) i sc * = I pLT * w pc + I qLT * w qc (13) These generated reference source currents (i sa * , i sb * and i sc * ) are compared with sensed generator source currents i sa , i sb and i sc and the output is processed through the hysteresis current controller to generate switching pulses to VSC.…”
Section: Control Of Vscmentioning
confidence: 99%
“…Multiple reference frame-based PLL is described in [7] utilises a decoupled network to avoid the effect of voltage unbalance in the grid. Adaptive filters (AFs) based on several synchronisation methods are discussed in [8][9][10][11][12]. The signals are pre-filtered then the magnitude, phase, and frequency are estimated.…”
Section: Introductionmentioning
confidence: 99%
“…The signals are pre-filtered then the magnitude, phase, and frequency are estimated. Multiple adaptive notch filters, multi-resonant frequency locked-loop (FLL) structures consisting of several generalised integrator (GI)-based AFs are reported in the literature for synchronisation to the grid [10]. Three-phase enhanced PLL (E-PLL)-based control proposed in [11] does not give accurate estimation under abnormal grid conditions.…”
Section: Introductionmentioning
confidence: 99%