Power quality improvement of single phase weak grid interfaced hybrid solar PV and wind system using double fundamental signal extracter‐based control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(10 citation statements)
references
References 26 publications
0
10
0
Order By: Relevance
“…A P&O‐based MPPT technique is employed for harvesting of optimal power from the available wind energy. The governing equation of P&O algorithm for wind system is given as, 17 ωref()m=ωref()m1+normalΔω0.24em{if0.12emdPω>00.12emand0.37emitalicdω>0or0.12emdPω<00.12emand0.37emitalicdω<00.12em ωref()m=ωref()m1italicΔω0.24em{if0.12emdPω>00.12emand0.37emitalicdω<0or0.12emdPω<00.12emand0.37emitalicdω>00.12em where, Δ ω is the speed error between the present estimated generator speed and earlier estimated generator speed.…”
Section: Control Algorithmsmentioning
confidence: 99%
“…A P&O‐based MPPT technique is employed for harvesting of optimal power from the available wind energy. The governing equation of P&O algorithm for wind system is given as, 17 ωref()m=ωref()m1+normalΔω0.24em{if0.12emdPω>00.12emand0.37emitalicdω>0or0.12emdPω<00.12emand0.37emitalicdω<00.12em ωref()m=ωref()m1italicΔω0.24em{if0.12emdPω>00.12emand0.37emitalicdω<0or0.12emdPω<00.12emand0.37emitalicdω>00.12em where, Δ ω is the speed error between the present estimated generator speed and earlier estimated generator speed.…”
Section: Control Algorithmsmentioning
confidence: 99%
“…The second mode aims to enhance the HS power quality by reducing the fluctuations of the output power for different weather conditions. This objective aims to smooth the total power produced by the hybrid system in a way that is different from unlike other works which deal the subject of energy quality for the hybrid systems through other techniques and according to other concepts, such as: the technique that applies the improved control strategy for power quality enhancement in standalone systems based on four-leg voltage source inverters (presented in [13]), the technique that aims to achieve the power quality improvement of single phase weak grid interfaced hybrid solar PV and wind system using double fundamental signal extracter-based control (presented in [14]), the technique aims to improve the voltage of remote connection using wind-solar farms equipped with new voltage control strategy based on virtual impedance monitoring (presented in [15]) and the technique which aims to improve the energy quality using a shunt active power filter (presented in [16]).…”
Section: Mppt and Power Quality Enhancement Of The Hybrid Power Systemmentioning
confidence: 99%
“…To synchronize with the grid, PLL must extract precise data about grid voltage, magnitude, and frequency. Poor performance of the conventional synchronization controller using the synchronous reference frame (SRF) PLL has been demonstrated under power quality problems such as voltage imbalance, disturbances, and the presence of low-order harmonics in the system [13]. The p-q theory was originally employed in a three-phase system.…”
Section: Introductionmentioning