2020
DOI: 10.25046/aj050630
|View full text |Cite
|
Sign up to set email alerts
|

Multi Operated Virtual Power Plant in Smart Grid

Abstract: The resources of active and reactive power for which can be obtained using an AC voltage controller with a phase-angle control for regulation of operating modes of the ohmic load of consumers, for example, distributed systems of electric space heating or electric water heating, etc. A method is proposed and the results of the analysis of the phase-angle control modes by gate turn off (GTO) thyristors of the AC voltage regulator, which provides the generation of virtual reactive power by consumers of active pow… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 20 publications
1
3
0
Order By: Relevance
“…Our result is somewhat similar to that reported in [13,14] where it is shown how for a resistive system without reactive elements with the help of ideal semiconductor gates, you can get the reactive power of both signs.…”
Section: Results Of Modeling a Phase Control Mode Of Single-operation...supporting
confidence: 91%
See 3 more Smart Citations
“…Our result is somewhat similar to that reported in [13,14] where it is shown how for a resistive system without reactive elements with the help of ideal semiconductor gates, you can get the reactive power of both signs.…”
Section: Results Of Modeling a Phase Control Mode Of Single-operation...supporting
confidence: 91%
“…This is the result of external exposure to voltage and power current. By analogy, reactive power in the main harmonics in a resistive electric circuit with controlled semiconductor gates [13,14], in addition to [20], can be called "reactive power of artificial shear".…”
Section: Results Of Modeling a Phase Control Mode Of Single-operation...mentioning
confidence: 99%
See 2 more Smart Citations
“…In [18,19], the results of the study of phase control modes by two-operation thyristors and power components of the resistive shunt element of the power grid are reported, and in [20] -the shunt element of the capacitive power grid. In the above studies, there is no information on the effectiveness of a possible similar adjustment of an inductive shunt element.…”
Section: Literature Review and Problem Statementmentioning
confidence: 99%