2012
DOI: 10.1016/j.apenergy.2011.08.011
|View full text |Cite
|
Sign up to set email alerts
|

Multi-machine transient modelling of wind farms: An essential approach to the study of fault conditions in the distribution network

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
2

Year Published

2015
2015
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 17 publications
0
9
0
2
Order By: Relevance
“…In order to protect the power electronic switches of the converter, U chopper is generally not greater than 1.1 times of udc$u_{{\rm{dc}}}^*$ [21]. Therefore, (normalΔudc(t))2${( {\Delta {u_{{\rm{dc}}}}(t)} )^2}$is much smaller than |udcΔudcfalse(tfalse)|$| {u_{{\rm{dc}}}^*\Delta {u_{{\rm{dc}}}}(t)} |$.…”
Section: Scope Of Application Of the Simplified Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to protect the power electronic switches of the converter, U chopper is generally not greater than 1.1 times of udc$u_{{\rm{dc}}}^*$ [21]. Therefore, (normalΔudc(t))2${( {\Delta {u_{{\rm{dc}}}}(t)} )^2}$is much smaller than |udcΔudcfalse(tfalse)|$| {u_{{\rm{dc}}}^*\Delta {u_{{\rm{dc}}}}(t)} |$.…”
Section: Scope Of Application Of the Simplified Modelmentioning
confidence: 99%
“…Most of equivalent methods of clustering the WTGs are according to the WPP structure, wind speed and states of low-voltage ride through of WTGs, and build the equivalent WTG model of each cluster. Three to five equivalent WTG models are generally used to replace a small-scale WPP with 50 WTGs to meet requirements of EMT analysis of short-circuit currents [18][19][20][21]. These aggregated equivalent methods can help reduce the amounts of WTG models in simulation to improve the simulation efficiency.…”
Section: Introductionmentioning
confidence: 99%
“…2, based on the available wind speed, the power (P T = P s + P g ) is delivered to the PCC via the rotor and stator circuits, respectively, when the rotor speed is greater than the synchronous speed ω r > ω s . For the reverse case, when ω r < ω s , only active power P s is transferred via the stator circuit to the PCC, while the active power P r is absorbed from the PCC through the power converter [45]. If vector control is applied to the synchronous stator frame in d-q orientation axis, based on the DFIG compensation methods and control strategy, then a model of the wind generator based on the fifth-order d-q representation could be achieved [46].…”
Section: Dfig Modelling and System Descriptionmentioning
confidence: 99%
“…The application of the conventional non‐linear sliding mode control (SMC) approach to improve the stability of the multimachine power network (MMPN) is presented in [13–16]. Selecting a perfect hyper‐plane for the non‐linear systems, for attaining an asymptotic stability is an important issue for the conventional SMCs.…”
Section: Introductionmentioning
confidence: 99%