Multi-frequency bioelectric impedance measurements for predicting body water compartments in patients with non-ascitic liver cirrhosis

Abstract: We assessed total body water (TBW) and extracellular water (ECW) in thirty-four non-ascitic cirrhotics and twenty healthy controls by *H,O and Br dilution. In the same subjects, bioelectric impedance (BI) was recorded at multiple frequencies. Body hydration was similar for controls (mean 55.6 (SD 67)), lesssevere cirrhotics (Child-Pugh classification A; CPA; n 21, mean 56.2 (SD 6.2)) and moderately-severe cirrhotics (Child-Pugh classification B; CPB; n 13, mean 57.2 (SD 5.4)). However, intracellular water stan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
9
0

Year Published

1997
1997
2012
2012

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(11 citation statements)
references
References 22 publications
2
9
0
Order By: Relevance
“…Our obese children had a lower TBW% and an higher ECW% as compared to controls and ZI allowed a reasonably good prediction of TBW but not of ECW on the pooled sample. Our study con®rms therefore that BIA is sensitive to changes in body water distribution and that it offers a more accurate prediction of ECW in groups with the lower variability in ECW% (Borghi et al, 1996). It should nonetheless be noted that all of the given equations need to be validated on external samples of children before being employed in clinical practice.…”
Section: Discussionsupporting
confidence: 58%
“…Our obese children had a lower TBW% and an higher ECW% as compared to controls and ZI allowed a reasonably good prediction of TBW but not of ECW on the pooled sample. Our study con®rms therefore that BIA is sensitive to changes in body water distribution and that it offers a more accurate prediction of ECW in groups with the lower variability in ECW% (Borghi et al, 1996). It should nonetheless be noted that all of the given equations need to be validated on external samples of children before being employed in clinical practice.…”
Section: Discussionsupporting
confidence: 58%
“…Previous studies of animals and healthy humans indicated that measurements of body water using multiple‐frequency BIA are reliable 10 . However, reports of the use of multiple‐frequency BIA for the assessment of body water compartments in cirrhotic patients with ascites are limited 24 . Lehnert et al .…”
Section: Discussionmentioning
confidence: 99%
“…10 However, reports of the use of multiple-frequency BIA for the assessment of body water compartments in cirrhotic patients with ascites are limited. 24 Lehnert et al found that ECW and TBW (as determined by isotope methods) were predicted accurately by multiplefrequency BIA (r = 0.73 and 0.89, respectively). 13 However, they noted that the 95% confidence interval for the limits of agreement between the multiplefrequency BIA and isotope methods was acceptable for the control group (1 5%) but was slightly higher for the cirrhotic group (1 9%).…”
Section: E Stimation Of Body Water Compartments Ismentioning
confidence: 96%
“…Because there is potential for between-subject variation in these factors, this model does not accurately predict TBW in altered fluid balance. 9 Eleven validation studies using discrete multifrequency BIA to predict TBW or ECW have been published in various clinical populations including growth-hormone deficiency, 62 Duchenne muscular dystrophy, 63 spinal cord injury, 64 the elderly, 43,[65][66][67] healthy Ethiopians, 68 nonascitic cirrhotics, 69 healthy subjects given diuretics, 70 and children with juvenile rheumatoid arthritis. 71 The results are so variable that no conclusions can be made regarding the validity of one frequency over another in the prediction of body fluid compartments.…”
Section: Discrete Multifrequency Serial Modelsmentioning
confidence: 99%