2014
DOI: 10.1016/j.nima.2014.05.126
|View full text |Cite
|
Sign up to set email alerts
|

Multi-channel data acquisition system with absolute time synchronization

Abstract: A low-cost, stand-alone Global-Positioning-System-time-synchronized data acquisition system is described. The constructed prototype allows recoding up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. Additionally, two digital readouts of external sensors can be acquired. A complete data set is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1
1

Relationship

5
3

Authors

Journals

citations
Cited by 33 publications
(14 citation statements)
references
References 15 publications
0
14
0
Order By: Relevance
“…The outputs of the magnetometers are acquired using custom-made devices based on Trimble Resolution-T GPS (Global Positioning System) time receivers [55]. The data acquisition devices provides time markers separated by one second with a precision of about 80 ns synchronized with a quartz clock built into the devices.…”
Section: Experimental Apparatusmentioning
confidence: 99%
“…The outputs of the magnetometers are acquired using custom-made devices based on Trimble Resolution-T GPS (Global Positioning System) time receivers [55]. The data acquisition devices provides time markers separated by one second with a precision of about 80 ns synchronized with a quartz clock built into the devices.…”
Section: Experimental Apparatusmentioning
confidence: 99%
“…First, in the preprocessing stage, a rolling average and filters are applied to the raw data from the GNOME magnetometer, which are originally recorded by the GPS-synchronized data-acquisition system at the rate of 512 samples per second (ref. 25 ). The rolling average is characterized by a 20 s time constant.…”
Section: Methodsmentioning
confidence: 99%
“…1 . The measurements from the magnetometers are recorded with custom data-acquisition systems 25 ; synchronized to the global positioning system (GPS) time; and uploaded to servers located in Mainz, Germany, and Daejeon, South Korea. Descriptions of the operational principles and characteristics of GNOME magnetometers are presented in Methods, Extended Data Table 1 , and ref.…”
Section: Mainmentioning
confidence: 99%
“…It is composed of three stages to identify events likely to be produced by ALP domain-wall crossings: preprocessing, velocity scanning, and postselection [29]. First, in the preprocessing stage, a rolling average and filters are applied to the GNOME magnetometer raw data which are originally recorded by the GPS-synchronized data-acquisition system at a rate of 512 samples/s [25]. The rolling average is characterized by a 20 s time constant.…”
Section: Methodsmentioning
confidence: 99%