2014 IEEE/ASME International Conference on Advanced Intelligent Mechatronics 2014
DOI: 10.1109/aim.2014.6878063
|View full text |Cite
|
Sign up to set email alerts
|

Multi-applications of a magnet configuration in actuating capsule endoscope

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 19 publications
0
11
0
Order By: Relevance
“…This higher flux density would allow an increase in the operating distance. In addition, this optimal magnetic structure made of only radially magnetized ASMs would impart a peak torque of approximately 10 [mNm] to the IPM. This higher peak torque would allow a further miniaturization of the IPM.…”
Section: B Magnetic Torquementioning
confidence: 99%
See 1 more Smart Citation
“…This higher flux density would allow an increase in the operating distance. In addition, this optimal magnetic structure made of only radially magnetized ASMs would impart a peak torque of approximately 10 [mNm] to the IPM. This higher peak torque would allow a further miniaturization of the IPM.…”
Section: B Magnetic Torquementioning
confidence: 99%
“…For example, a ring-shaped IPM to control the trajectory of a CE was used in [8,9], ring-shaped IPMs to deploy legs as a locomotion system for a CE were used in [10,11], cylindrical IPMs for biopsy purposes were used in [2,6] and two spherical IPMs to achieve wireless insufflation were employed in [7]. Furthermore, two cylindrical IPMs to release drug from a chamber in a prototype of CE were reported in [12,13].…”
Section: Introductionmentioning
confidence: 99%
“…3. Cylindrical magnets are commonly used in medical applications [10][11][12][13][14][15]. Arc-shaped magnets have shown promising results in the transmission of high density torques [20,21].…”
Section: Clinical Procedurementioning
confidence: 99%
“…In all those studies [3,[10][11][12][13][14][15], the maximum operating distance is 150 mm which is not large enough for a realistic WCE application. In order to overcome this problem, we propose a magnetomechanical system made of an array of multiple permanent magnets, which enhances the magnetic field when the operating distance is increased to a more realistic distance of 240 mm.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation