We present design and experimental performance results for a novel mechanism for robotic legged locomotion at the mesoscale (from hundreds of microns to tens of centimeters). The new mechanism is compact and strikes a balance between conflicting design objectives, exhibiting high foot forces and low power consumption. It enables a small robot to traverse a compliant, slippery, tubular environment, even while climbing against gravity. This mechanism is useful for many mesoscale locomotion tasks, including endoscopic capsule robot locomotion in the gastrointestinal tract. It has enabled fabrication of the first legged endoscopic capsule robot whose mechanical components match the dimensions of commercial pill cameras (11 mm diameter by 25 mm long). A novel slot-follower mechanism driven via lead screw enables the mechanical components of the capsule robot to be as small while simultaneously generating 0.63 N average propulsive force at each leg tip. In this paper, we describe kinematic and static analyses of the lead screw and slot-follower mechanisms, optimization of design parameters, and experimental design and tuning of a gait suitable for locomotion. A series of ex vivo experiments demonstrate capsule performance and ability to traverse the intestine in a manner suitable for inspection of the colon in a time period equivalent to standard colonoscopy.
This paper describes a novel approach to capsular endoscopy that takes advantage of active magnetic locomotion in the gastrointestinal tract guided by an anthropomorphic robotic arm. Simulations were performed to select the design parameters allowing an effective and reliable magnetic link between the robot end-effector (endowed with a permanent magnet) and the capsular device (endowed with small permanent magnets). In order to actively monitor the robotic endoluminal system and to efficiently perform diagnostic and surgical medical procedures, a feedback control based on inertial sensing was also implemented. The proposed platform demonstrated to be a reliable solution to move and steer a capsular device in a slightly insufflated gastrointestinal lumen.
The gastrointestinal tract is home to some of the most deadly human diseases. Exacerbating the problem is the difficulty of accessing it for diagnosis or intervention and the concomitant patient discomfort. Flexible endoscopy has established itself as the method of choice and its diagnostic accuracy is high, but there remain technical limitations in modern scopes, and the procedure is poorly tolerated by patients, leading to low rates of compliance with screening guidelines. Although advancement in clinical endoscope design has been slow in recent years, a critical mass of enabling technologies is now paving the way for the next generation of gastrointestinal endoscopes. This review describes current endoscopes and provides an overview of innovative flexible scopes and wireless capsules that can enable painless endoscopy and/or enhanced diagnostic and therapeutic capabilities. We provide a perspective on the potential of these new technologies to address the limitations of current endoscopes in mass cancer screening and other contexts and thus to save many lives. Review in Advance first posted online on May 29, 2012. (Changes may still occur before final publication online and in print.) Changes may still occur before final publication online and in print
Abstract-This paper presents the design and fabrication of Single-Port lapaRoscopy bImaNual roboT (SPRINT), a novel teleoperated robotic system for minimally invasive surgery. SPRINT, specifically designed for single-port laparoscopy, is a high-dexterity miniature robot, able to reproduce the movement of the hands of the surgeon, who controls the system through a master interface. It comprises two arms with six degrees of freedom (DOFs) that can be individually inserted and removed in a 30-mm-diameter umbilical access port. The system is designed to leave a central lumen free during operations, thus allowing the insertion of other laparoscopic tools. The four distal DOFs of each arm are actuated by on-board brushless dc motors, while the two proximal DOFs of the shoulder are actuated by external motors. The constraints generated by maximum size and power requirements led to the design of compact mechanisms for the actuation of the joints. The wrist is actuated by three motors hosted in the forearm, with a peculiar differential mechanism that allows us to have intersecting rollpitch-roll axes. Preliminary tests and validations were performed ex vivo by surgeons on a first prototype of the system. Index Terms-Bimanual robot, miniature robotic arm, minimally invasive surgery, robotic surgery, single-port laparoscopy (SPL).
Pose estimation methods for robotically guided magnetic actuation of capsule endoscopes have recently enabled trajectory following and automation of repetitive endoscopic maneuvers. However, these methods face significant challenges in their path to clinical adoption including the presence of regions of magnetic field singularity, where the accuracy of the system degrades, and the need for accurate initialization of the capsule's pose. In particular, the singularity problem exists for any pose estimation method that utilizes a single source of magnetic field if the method does not rely on the motion of the magnet to obtain multiple measurements from different vantage points. We analyze the workspace of such pose estimation methods with the use of the point-dipole magnetic field model and show that singular regions exist in areas where the capsule is nominally located during magnetic actuation. Since the dipole model can approximate most magnetic field sources, the problem discussed herein pertains to a wider set of pose estimation techniques. We then propose a novel hybrid approach employing static and time-varying magnetic field sources and show that this system has no regions of singularity. The proposed system was experimentally validated for accuracy, workspace size, update rate and performance in regions of magnetic singularity. The system performed as well or better than prior pose estimation methods without requiring accurate initialization and was robust to magnetic singularity. Experimental demonstration of closed-loop control of a tethered magnetic device utilizing the developed pose estimation technique is provided to ascertain its suitability for robotically guided capsule endoscopy. Hence, advances in closed-loop control and intelligent automation of magnetically actuated capsule endoscopes can be further pursued toward clinical realization by employing this pose estimation system.
Eighty percent of medical robotics papers have been published in the past decade—What has been accomplished?
Early diagnosis of colorectal cancer substantially improves survival. However, over half of cases are diagnosed late due to the demand for colonoscopy-the 'gold standard' for screening-exceeding capacity. Colonoscopy is limited by the outdated design of conventional endoscopes, which are associated with high complexity of use, cost and pain. Magnetic endoscopes are a promising alternative and overcome the drawbacks of pain and cost, but they struggle to reach the translational stage as magnetic manipulation is complex and unintuitive. In this work, we use machine vision to develop intelligent and autonomous control of a magnetic endoscope, enabling non-expert users to effectively perform magnetic colonoscopy in vivo. We combine the use of robotics, computer vision and advanced control to offer an intuitive and effective endoscopic system. Moreover, we define the characteristics required to achieve autonomy in robotic endoscopy. The paradigm described here can be adopted in a variety of applications where navigation in unstructured environments is required, such as catheters, pancreatic endoscopy, bronchoscopy and gastroscopy. This work brings alternative endoscopic technologies closer to the translational stage, increasing the availability of early-stage cancer treatments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.