2016
DOI: 10.1117/1.jbo.21.7.071116
|View full text |Cite
|
Sign up to set email alerts
|

Mueller-matrix of laser-induced autofluorescence of polycrystalline films of dried peritoneal fluid in diagnostics of endometriosis

Abstract: This research presents investigation results of the diagnostic efficiency of an azimuthally stable Mueller-matrix method of analysis of laser autofluorescence of polycrystalline films of dried uterine cavity peritoneal fluid. A model of the generalized optical anisotropy of films of dried peritoneal fluid is proposed in order to define the processes of laser autofluorescence. The influence of complex mechanisms of both phase (linear and circular birefringence) and amplitude (linear and circular dichroism) anis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
4
1

Relationship

3
7

Authors

Journals

citations
Cited by 39 publications
(8 citation statements)
references
References 39 publications
(63 reference statements)
0
8
0
Order By: Relevance
“…Here: • LD and LB -linear dichroism and birefringence for the direction of the optical axis light amplitude; Such a parameters are in particular investigated for optically thin (non-depolarizing) layers of the histological sections of biological tissues and films of biological liquids [20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36] . For depolarizing layers such data is not obtained.…”
Section: Introduction 1brief Theory Of the Methodsmentioning
confidence: 99%
“…Here: • LD and LB -linear dichroism and birefringence for the direction of the optical axis light amplitude; Such a parameters are in particular investigated for optically thin (non-depolarizing) layers of the histological sections of biological tissues and films of biological liquids [20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36] . For depolarizing layers such data is not obtained.…”
Section: Introduction 1brief Theory Of the Methodsmentioning
confidence: 99%
“…The actual direction in laser polarimetric diagnostics [1][2][3][4][5][6][7][8][9][10][11] of biological objects is the development of matrix methods [12][13][14][15], which provide the most complete information about the polycrystalline structure [16][17][18][19][20][21] of films of biological fluids of human organs. We study possibilities of the development and experimental testing of the Jones matrix (JM) mapping method for polycrystalline layers of basic amino acids of the human body in order to obtain parameters for the differential diagnosis of pathological conditions.…”
Section: Introductionmentioning
confidence: 99%
“…Here, based on the statistical approach, correlations are found between the average, dispersion, skewness, and kurtosis, which characterize the phase-inhomogeneous layers and Mueller-matrix elements of the distributions [13][14][15]. On this basis, diagnostic criteria for cancer and other pathologies of human organs were found [16][17][18][19]. However, real biological media usually have depolarizing effect on the laser beam, propagating in them [20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%