2009
DOI: 10.1111/j.1749-6632.2009.05063.x
|View full text |Cite
|
Sign up to set email alerts
|

MRI Measures of Alzheimer's Disease and the AddNeuroMed Study

Abstract: Here we describe the AddNeuroMed multicenter magnetic resonance imaging (MRI) study for longitudinal assessment in Alzheimer's disease (AD). The study is similar to a faux clinical trial and has been established to assess longitudinal MRI changes in AD, mild cognitive impairment (MCI), and healthy control subjects using an image acquisition protocol compatible with the Alzheimer's Disease Neuroimaging Initiative (ADNI). The approach consists of a harmonized MRI acquisition protocol across centers, rigorous qua… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
117
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
6
2
1

Relationship

3
6

Authors

Journals

citations
Cited by 125 publications
(118 citation statements)
references
References 10 publications
(11 reference statements)
1
117
0
Order By: Relevance
“…important in many neurological applications. Diseases such as multiple sclerosis [1][2][3], Alzheimer's disease [4] and dementia [5,6] are associated with global and local brain atrophy. A reliable volume estimation of whole-brain grey matter (GM), white matter (WM) and cerebro-spinal fluid (CSF) allows accurate individual follow-up as well as quantitative comparison with reference groups [7].…”
Section: Introductionmentioning
confidence: 99%
“…important in many neurological applications. Diseases such as multiple sclerosis [1][2][3], Alzheimer's disease [4] and dementia [5,6] are associated with global and local brain atrophy. A reliable volume estimation of whole-brain grey matter (GM), white matter (WM) and cerebro-spinal fluid (CSF) allows accurate individual follow-up as well as quantitative comparison with reference groups [7].…”
Section: Introductionmentioning
confidence: 99%
“…Finally, the MRI sites and data coordination center worked closely together with continuous feedback as data were acquired. All MRI centers were trained to perform quality control at their site at the time the images were acquired with particular emphasis on full brain coverage, image wrap around, subject motion artifacts, contrast between gray and white matter, and image nonuniformities [29] . All scanners remained within specification for the ADNI phantom throughout the course of the study.…”
Section: Methodsmentioning
confidence: 99%
“…Most common artifacts specific to DTI acquisitions include large signal dropouts due to susceptibility effects, geometric distortions and misalignment among the diffusion-weighted images [63]. Although some of these artifacts can be attenuated by post-processing techniques, an initial quality control can detect severely corrupted images that have to be repeated (on-site quality control) or excluded from the study (central quality control) [126]. Besides direct quality control of the imaging output, phantom-based monitoring of individual scanner performance is an effective way to control for consistency of image quality over the course of the study [80].…”
Section: Standardization Of Acquisition Protocolsmentioning
confidence: 98%
“…A central component of multi-centric imaging studies should be a rigorous quality control, including visual and/or automated tests for typical MR imaging artifacts, such as partial coverage of the brain, blurring due to subject motion, severe image non-uniformities or irregularities in tissue contrast [122,126]. Most common artifacts specific to DTI acquisitions include large signal dropouts due to susceptibility effects, geometric distortions and misalignment among the diffusion-weighted images [63].…”
Section: Standardization Of Acquisition Protocolsmentioning
confidence: 99%