2014
DOI: 10.1109/tns.2013.2294829
|View full text |Cite
|
Sign up to set email alerts
|

MRI Investigation of the Linkage Between Respiratory Motion of the Heart and Markers on Patient’s Abdomen and Chest: Implications for Respiratory Amplitude Binning List-Mode PET and SPECT Studies

Abstract: Respiratory motion of the heart impacts the diagnostic accuracy of myocardial-perfusion emission-imaging studies. Amplitude binning has come to be the method of choice for binning list-mode based acquisitions for correction of respiratory motion in PET and SPECT. In some subjects respiratory motion exhibits hysteretic behavior similar to damped non-linear cyclic systems. The detection and correction of hysteresis between the signals from surface movement of the patient’s body used in binning and the motion of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
10
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 35 publications
(46 reference statements)
1
10
0
Order By: Relevance
“…This trend was observed for all 19 volunteers of our previous study. 19 Therein a strong pairwise correlation was observed over all-pairs of comparison between the motions of the five chest markers which implies that any of the chest markers could be used for data analysis. Herein, the signal obtained from the chest marker closest to the heart was considered for the purpose of modeling and analysis.…”
Section: B External Respiratory Motion-tracking System: Vtsmentioning
confidence: 95%
See 4 more Smart Citations
“…This trend was observed for all 19 volunteers of our previous study. 19 Therein a strong pairwise correlation was observed over all-pairs of comparison between the motions of the five chest markers which implies that any of the chest markers could be used for data analysis. Herein, the signal obtained from the chest marker closest to the heart was considered for the purpose of modeling and analysis.…”
Section: B External Respiratory Motion-tracking System: Vtsmentioning
confidence: 95%
“…The MRI was configured as an external remote-control device which was used to trigger data capture automatically on the . Once established in this way, we have previously determined 19 that synchrony between the clocks of the MRI and  is maintained during the duration of acquisition by determining the Spearman rank-order correlation coefficient between the chest wall navigator signal and that from the chest marker nearest the navigator position. Example plots of the AP motion of the markers for one subject are shown in Fig.…”
Section: B External Respiratory Motion-tracking System: Vtsmentioning
confidence: 99%
See 3 more Smart Citations