1999
DOI: 10.1002/(sici)1522-2594(199907)42:1<141::aid-mrm19>3.0.co;2-i
|View full text |Cite
|
Sign up to set email alerts
|

MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: Demonstration of feasibility at 0.2 T

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
29
0

Year Published

2000
2000
2009
2009

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 61 publications
(33 citation statements)
references
References 28 publications
4
29
0
Order By: Relevance
“…The medial lobe of the liver was ablated with a 19‐gauge needle electrode (Radionics®, Burlington, MA) at 90 ± 3°C for 3 min to create an ablation zone of approximately 6 mm in diameter. This RF ablation procedure is similar to those described previously 9, 10. A short segment of a doxorubicin millirod was implanted into the ablated lobe.…”
Section: Methodsmentioning
confidence: 99%
“…The medial lobe of the liver was ablated with a 19‐gauge needle electrode (Radionics®, Burlington, MA) at 90 ± 3°C for 3 min to create an ablation zone of approximately 6 mm in diameter. This RF ablation procedure is similar to those described previously 9, 10. A short segment of a doxorubicin millirod was implanted into the ablated lobe.…”
Section: Methodsmentioning
confidence: 99%
“…Goldberg et al (11) proved in a porcine model that a decrease in liver perfusion leads to an increase in lesion size using computed tomography (CT) for guidance. Our own group established a rabbit model for RF ablations of the liver (12) concluding that thermal lesion size can be accurately monitored using an open C‐arm shaped 0.2‐T MRI system.…”
mentioning
confidence: 99%
“…In this work, two types of radial k‐space keyhole schemes are proposed and compared for their potential use in IMRI applications in which needle‐like devices are percutaneously introduced into the patient. Two existing widely performed example applications include biopsy (43–45) and thermal ablation of lesions (37–40, 46, 47). This project does not explore contrast requirements for IMRI procedures because the sequence type (FISP: unspoiled steady state, also termed GRASS) has a well‐established reputation for generating sufficient contrast between normal and pathologic tissue in many IMRI‐guided procedures (36–39, 43, 44, 48).…”
Section: Discussionmentioning
confidence: 99%
“…A normal 2DFT unspoiled steady‐state free precession (SSFP) sequence [fast imaging with steady‐state free precession (35) (FISP, also termed GRASS)], shown previously to be useful in MRI guidance and monitoring (36–39), was modified to achieve a 180‐view, 256 samples/view radial k‐space data acquisition (Fig. 3).…”
Section: Methodsmentioning
confidence: 99%