Moving from fast to ballistic gradient in liquid chromatography/tandem mass spectrometry pharmaceutical bioanalysis: matrix effect and chromatographic evaluations

Abstract: The paper describes the steps taken by the authors to move from a fast to a ballistic gradient in routine liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis of plasma samples from pharmacokinetic (PK) profiling of new chemical entities. The reduction of column dimensions from 50 T 4.6 mm to 30 T 2.1 mm followed by optimization of chromatographic separation led to a decrease in the typical runtime from 5 (fast) to 2 min (ballistic) using an API4000 tandem mass spectrometer in Turbo Ionspray mode… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
20
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 37 publications
(20 citation statements)
references
References 24 publications
0
20
0
Order By: Relevance
“…These include using sub-2 m particle columns [1,2], ballistic gradients [3,4], fast isocratic LC/MS runs [5], increased flow rates using shorter columns [6], and the use of monolithic [7] or fused-core [8][9][10][11][12] HPLC columns. With the recent advent of direct atmospheric pressure sampling techniques for MS, various groups have also explored assays that may require little or no sample preparation, and introduce samples to the MS with no chromatography, using methods such as DESI [13,14] and DART [15,16].…”
Section: Introductionmentioning
confidence: 99%
“…These include using sub-2 m particle columns [1,2], ballistic gradients [3,4], fast isocratic LC/MS runs [5], increased flow rates using shorter columns [6], and the use of monolithic [7] or fused-core [8][9][10][11][12] HPLC columns. With the recent advent of direct atmospheric pressure sampling techniques for MS, various groups have also explored assays that may require little or no sample preparation, and introduce samples to the MS with no chromatography, using methods such as DESI [13,14] and DART [15,16].…”
Section: Introductionmentioning
confidence: 99%
“…Finally, the best 284 chromatographic conditions were achieved using an isocratic mode of acetonitrile: 285 0.1% formic acid (50:50, v/v) at a flow rate of 0.3 ml/min. Increased lifetime of 286 smaller columns, reduction of instrument time and less eluent consumption together 287with a cleaner mass source thanks to a smaller injection volume make this analytical 288 approach even more attractive[10]. All the analytes and IS are eluted in the narrow 289 range of retention times (0.30-0.67 min.)…”
mentioning
confidence: 99%
“…In order to achieve ultra-fast run times, the use of a 'ballistic' gradient was required in combination with high flow-rate and a short column. This type of approach has been reported by several authors [9,10] and was successfully applied herein.…”
Section: Introductionmentioning
confidence: 84%