Proceedings of 1st EPS Conference on Plasma Diagnostics — PoS(ECPD2015) 2016
DOI: 10.22323/1.240.0032
|View full text |Cite
|
Sign up to set email alerts
|

Motional Stark Effect Measurements Of The Local Magnetic Field In High Temperature Fusion Plasmas

Abstract: The utilization of the Motional Stark Effect (MSE) experienced by the neutral hydrogen or deuterium injected into magnetically confined high temperature plasmas is a well established technique to infer the internal magnetic field distribution of fusion experiments. The different properties of the Stark multiplet allow inferring, both the magnetic field strength and the orientation of the magnetic field vector. Besides recording the full MSE spectrum, several types of polarimeters have been developed to measure… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2017
2017

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 46 publications
0
2
0
Order By: Relevance
“…However, the positions of those mirrors do not necessarily fulfil the condition ∆α = 0. In order to minimize the influence of the mirror on the polarization measurement, in ASDEX Upgrade the mirror is provided with a dielectric coating which for the wavelength range and the angular range given maximizes the reflectivity [49]. In addition, in ASDEX Upgrade the mirror is protected against coatings by an exchangeable glass window in front of the mirror.…”
Section: Measurement Of the Polarized Line Emission 41 Measurement Te...mentioning
confidence: 99%
“…However, the positions of those mirrors do not necessarily fulfil the condition ∆α = 0. In order to minimize the influence of the mirror on the polarization measurement, in ASDEX Upgrade the mirror is provided with a dielectric coating which for the wavelength range and the angular range given maximizes the reflectivity [49]. In addition, in ASDEX Upgrade the mirror is protected against coatings by an exchangeable glass window in front of the mirror.…”
Section: Measurement Of the Polarized Line Emission 41 Measurement Te...mentioning
confidence: 99%
“…The magneto-hydrodynamic force balance → → ∇ = × p j B describes a condition for stationary magnetic equilibria. Changes in the fast ion population can cause diamagnetic effects which decrease the toroidal magnetic field by about 1% [3,4], and these small effects, though difficult to detect, are of great importance for the local state of the plasma. Even more difficult is the measurement of changes to the local poloidal magnetic field (due to current profile reconfiguration) [3,5,6].…”
Section: Introductionmentioning
confidence: 99%