2017
DOI: 10.1016/j.snb.2017.04.193
|View full text |Cite
|
Sign up to set email alerts
|

MoS2-based all-fiber humidity sensor for monitoring human breath with fast response and recovery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
62
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 155 publications
(62 citation statements)
references
References 25 publications
0
62
0
Order By: Relevance
“…The data from the response (recovery) stage were fitted by the exponential equation P=P1+A1exp[tt1τresponse](P=P2+A2exp[tt2τrecovery]), where P , P 1 , and P 2 represent the optical power; A 1 and A 2 are the fitting coefficients; and t 1 and t 2 are the times. A very fast response time of 7 ms was achieved, indicating a significantly enhanced responsive characteristic compared with other reported humidity sensors using 2D materials (Table ) . It is expected that the improvement in the surface area of BP nanosheets would lead to increased responsivity.…”
Section: A Comparison Of Response Time Obtained By Different Methodsmentioning
confidence: 73%
See 1 more Smart Citation
“…The data from the response (recovery) stage were fitted by the exponential equation P=P1+A1exp[tt1τresponse](P=P2+A2exp[tt2τrecovery]), where P , P 1 , and P 2 represent the optical power; A 1 and A 2 are the fitting coefficients; and t 1 and t 2 are the times. A very fast response time of 7 ms was achieved, indicating a significantly enhanced responsive characteristic compared with other reported humidity sensors using 2D materials (Table ) . It is expected that the improvement in the surface area of BP nanosheets would lead to increased responsivity.…”
Section: A Comparison Of Response Time Obtained By Different Methodsmentioning
confidence: 73%
“…To further verify the response characteristic of the sensor, a single expiratory pulse was applied to the BP‐coated ESMF . The time‐dependent power variation is shown in Figure b.…”
Section: A Comparison Of Response Time Obtained By Different Methodsmentioning
confidence: 99%
“…c) SEM image of MoS 2 ‐based fiber humidity sensor and breathing monitoring results for the bare etched single‐mode fiber (ESMF) and MoS 2 ‐coated ESMF. Reproduced with permission . Copyright 2017, Elsevier.…”
Section: Human Chemical Signals Detectionmentioning
confidence: 99%
“…Du et al fabricated a MoS 2 ‐coated etched single‐mode fiber (ESMF) humidity sensor with a diameter of ≈18 µm and a length of ≈15 mm (Figure c) . Because of the interaction between MoS 2 nanosheets and the evanescent field, the optical frequency conductivity changes with relative humidity variation, leading to the power change of transmission light.…”
Section: Human Chemical Signals Detectionmentioning
confidence: 99%
“…The ever increasing research done on TMDC materials offer an intriguing alternative. For example, Du et al placed exfoliated MoS2 flakes onto the core of a standard step index optical fiber, which had been exposed via etching 9 . The power guided down the fiber was modulated by the humidity of the surrounding area, with a quick response time.…”
Section: Introductionmentioning
confidence: 99%