1997
DOI: 10.1007/pl00008025
|View full text |Cite
|
Sign up to set email alerts
|

Morphologische Korrelation der funktionellen Bauchwandmechanik nach Mesh-Implantation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0
3

Year Published

2002
2002
2015
2015

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 0 publications
1
4
0
3
Order By: Relevance
“…Synthetic materials such as polypropylene induce an intensive inflammatory response, 8,9 which may be responsible for poor tissue compatibility, and lead to adhesion formation, infection and other complications, 10 such as dyspareunia, pain, bladder dysfunction, stone formation and infection, bowel obstruction and abdominal pain. 11 There are newer implant materials derived from biological sources available, one of which is porcine small intestine submucosa (SIS)-derived, non-cross-linked collagen matrix, marketed as SIS (Cook, Strombeek-Bever, Belgium).…”
Section: Introductionmentioning
confidence: 99%
“…Synthetic materials such as polypropylene induce an intensive inflammatory response, 8,9 which may be responsible for poor tissue compatibility, and lead to adhesion formation, infection and other complications, 10 such as dyspareunia, pain, bladder dysfunction, stone formation and infection, bowel obstruction and abdominal pain. 11 There are newer implant materials derived from biological sources available, one of which is porcine small intestine submucosa (SIS)-derived, non-cross-linked collagen matrix, marketed as SIS (Cook, Strombeek-Bever, Belgium).…”
Section: Introductionmentioning
confidence: 99%
“…These consequences of the biological response to the foreign material are markedly influenced by the amount of incorporated material, particularly depending on the surface and the pore size. 5,6 Theoretical considerations, as well as the intraoperatively measured tensile strength during hernia repair, indicate that most of the currently available mesh materials are oversized with inappropriate elastic properties. 7 Both animal experiments and clinical experience have shown that adapting the mesh to the physiological demands by reducing the amount of introduced material (amount of polypropylene Ͻ 30 g/m 2 ) and enlarging the pore size (as in a multifilament low-weight mesh) results in a significant improvement in biocompatibility.…”
Section: Introductionmentioning
confidence: 99%
“…Meshes, finden in zunehmendem Maß Anwendung bei der Versorgung von Hernien, insbesondere von Narbenhernien. Ihre primäre Aufgabe ist dabei die Verstärkung und Stabilisierung der Bauchwand, was durch den mechanischen Verschluss der Bruchlücke und die Induktion einer Narbenplatte mit dem Netz als zentralem Element erreicht wird [7,8,18]. Ihr Einsatz führte zu einer deutlichen Reduktion der Rezidivrate bei mit Meshes versorgten Narbenhernien bzw.…”
Section: Schlüsselwörterunclassified
“…Wäh-rend dazu zahlreiche Untersuchungen über die entzündlichen Fremdkörperreaktionen im Gewebe nach Implantation von Kunststoffen existieren [6,7,8,10,19], fehlen weitergehende Untersuchungen über die zellulären Reaktionen insbesondere auf molekularer Ebene. Deshalb mehren sich in letzter Zeit auch kritische Stimmen, die vor einem unkontrollierten Einsatz dieser Meshes warnen, da zu wenig über die Spätfolgen und eine mögliche Entartungstendenz bekannt ist [16], zumal tierexperimentell die Sarkominduktion durch alloplastisches Material eindeutig gesichert werden konnte [4,13,14].…”
Section: Schlüsselwörterunclassified